DR30GS, DR30GFS, DR30GIS, DR3GIFS

Document # PG05-007

Revised 09/13/12 Page 4/4

 

Distinctive 30” Wide

PLANNING

 

All Gas Ranges

GUIDE

10” (25.4 cm)

 

 

 

 

10” (25.4 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12” (30.5 cm)

2 1/2”

 

(6.4 cm)

1” (2.5 cm)

3 1/2”

(8.9 cm)

utility clearance behind range

ELECTRICAL REQUIREMENTS

Electrical Circuit

Total Connected

Required

Load

120 Vac, 60 Hz, 15 Amps.,

4.0 Amps. @

dedicated, grounded

120 Vac, 60 Hz

121/4”

(31.1 cm)

to

14 1/4”

6’ (183 cm)

(36.2 cm)

long

 

4 1/4”

(10.8 cm)

back of range

GAS SUPPLY PRESSURE REQUIREMENTS

Gas

Manifold

Min. Gas Supply

Max. Input

Type

Pressure* (WC)

Pressure (WC)

Pressure

Natural

5”

6”

1/2 psi

LP

10”

11”

1/2 psi

IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label.

The gas inlet on the regulator accommodates a 1/2” NPT gas line connection. The range can also accommodate a 3/4” NPT gas line connection by removing the 1/2” to 3/4” adapter on the regulator inlet.

All specifications subject to change without notice.