Installation Specifications

Installation Planning

warning

Observe all governing codes and ordinances during plan- ning and installation. Contact your local building depart- ment for further information.

important

Locate the junction box so that the oven may be easily disconnected in the event that it needs to be removed from the wall completely for service.

If the oven is not installed level it may deliver poor or inconsistent baking results.

A qualified technician must complete the installation of this built-in appliance. Proper installation is the respon- sibility of the customer.

Carefully check the location where the oven is to be installed. The oven should be placed for convenient access. Make certain that electrical power, meeting the specifications on page 4, can be provided in the selected location.

Dacor recommends installing the electrical junction box in the one of the locations shown.

Install the junction box in a location that allows the oven to be removed from the the cut out for service without being disconnected.

Plan the installation so that all minimum clearances are met or exceeded. Dimensions shown provide mini- mum clearances, unless otherwise noted. Be certain that proper clearance is provided for the oven door when it is in the open position according the Product Dimensions.

Cabinet cutout dimensions must be used as indicated. The specified minimum cabinet depth and width must be provided. The cabinet depth and width must com- pletely enclose the recessed portion of the oven.

All contact surfaces between the appliance and the cabi- net must be solid and level.

Provide a platform within the cabinet to support the oven. It must be installed level and straight. The top edge of the platform must be flush with the cut out at the front of the cabinet. There are no provisions to level the oven after it has been installed. 3/4” (1.9 cm) thick plywood is recommended.

Cabinet Dimensions

Model

Minimum Cabinet

Minimum Cut Out

Minimum Cut out

Number

Width (N)

Width (P)

Height (R)

EORS127/

27”

(68.6 cm)

25 ½” (64.8 cm)

 

MORS127

 

 

 

 

27 5/8” (70.2 cm)

EORS130/

30”

(76.2 cm)

28 ½” (72.4 cm))

 

MOCS130

 

 

 

 

 

EORS136

36” (91.4 cm)

34 ½” (87.6 cm)

27 ¾” (70.5 cm)

EORX227/

27” (68.6 cm)

25 ½” (64.8 cm)

 

MORX227

 

 

 

 

49 1/8” (124.8 cm)

 

 

 

 

EORX230/

30” (76.2 cm)

28 ½” (72.4 cm)

 

MORX230

 

 

 

 

 

 

 

 

 

X = Number of convection ovens, see page 3

 

 

Minimum Interior Cabinet Depth: 24” (61.0 cm)

6

Page 8
Image 8
Dacor EOR, MOR installation instructions Installation Specifications, Installation Planning, Cabinet Dimensions

MOR, EOR specifications

Dacor EOR and MOR are innovative solutions tailored for energy optimization and resource management in various industrial and commercial applications. These systems represent the forefront of modern technology, combining advanced features and methods to improve efficiency and sustainability.

The main feature of Dacor EOR (Energy Optimization Resource) is its ability to monitor and manage energy consumption in real-time. It employs sophisticated algorithms to analyze energy usage patterns, identify inefficiencies, and suggest adjustments that can lead to significant cost savings. By integrating AI and machine learning, the EOR system learns from historical data, allowing for progressive enhancements in energy management.

On the other hand, the Dacor MOR (Management of Resources) focuses on optimizing the use of natural resources, including water and raw materials. MOR employs a comprehensive approach, utilizing sensors and IoT (Internet of Things) technology to gather data on resource consumption. This data can be analyzed to provide insights into usage trends, enabling businesses to implement strategies that minimize waste and promote sustainability.

One of the standout technologies used in both EOR and MOR systems is the integration of predictive analytics. By forecasting energy and resource needs based on various variables such as time of year, production schedules, and weather patterns, these solutions can proactively manage resources before shortages or overages occur. This feature not only enhances operational efficiency but also supports environmental responsibility by reducing unnecessary consumption.

The Dacor solutions are also characterized by their user-friendly interfaces. Through intuitive dashboards, users can easily access real-time data, receive alerts, and analyze trends. This accessibility fosters a culture of accountability within organizations, encouraging all employees to engage in energy and resource conservation efforts.

Moreover, Dacor EOR and MOR systems are designed to be scalable, accommodating the needs of businesses of all sizes. Whether it's a small enterprise or a large corporation, the adaptability of these systems allows for tailored implementations that fit specific operational requirements.

In summary, Dacor EOR and MOR are at the cutting edge of energy and resource management technology. With their advanced monitoring capabilities, predictive analytics, and user-friendly design, they not only help businesses optimize their consumption but also contribute to a more sustainable future by reducing environmental impact and promoting efficient resource use. These solutions stand as essential tools for modern enterprises aiming to enhance their operational efficiency while aligning with sustainability goals.