ER30D/ER30DSR

 

Epicure™ Ranges

PLANNING

 

GUIDE

103107

2/3

F

CUT-OUT DIMENSIONS

“F”“G”

36” (914mm)* 30 1/16” (916mm)* 30” (762mm)**

* Recommended

** Minimum

24”Typ. (610mm)

25”Typ. (635mm)

G

All tolerances: +1/16”, -0 (+1.6mm, -0)

Cabinet cut-out dimensions

Gas and Electrical Service

The shaded area shown denotes the location of the gas inlet and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the

location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible gas valve locations.

An external manual shut-off valve must be installed between the gas inlet and the range, for the purpose of turning on or shutting off gas to the appliance.

The installation must allow for the following:

Access to the gas shut-off valve when the unit is installed.

Access to the remote circuit breaker panel/fuse box, when the range is in place.

The gas supply piping and shut-off valve, and the electrical junction box/receptacle must be located so they do not interfere with the range when it is installed.

The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected.

Non-Combustible

10”

Min.

 

 

 

 

 

7/16”

 

 

 

 

(254mm)

 

 

 

 

 

Rear Wall

 

 

 

 

 

(11mm)

Both

Sides

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29 1/4” (743mm)

Countertop

Opening23 9/16” (598mm)

30 1/16” (764mm)

Cabinet

Opening

Combustible Side

Wall Above Range

1”

(25mm)

Cabinet cut-out dimensions self rimming installation

 

 

 

 

10” Min.

 

 

 

 

1/4” Min.

 

 

 

 

 

 

 

 

 

Rear Wall

(254mm)

 

 

 

 

 

Both Sides

 

 

 

 

(6mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27 7/8” (708mm)

 

 

 

 

 

 

 

2 13/16” (71mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

ERV Opening

 

 

 

 

 

 

 

 

29 1/4” (743mm)

Countertop

Opening24 1/16”

(611mm)

30 1/16” (764mm)

Cabinet

Opening

Combustible Side

Wall Above Range

Minimum Cabinet depth: 27 1/8” (688mm)

1”

Minumum Countertop depth: 28 1/8” (714mm)

(25mm)

Cabinet cut-out dimensions self rimming installation with erv raised vent

Web: http://www.Dacor.com

Specifications are subject to change without notice.

5.8

Corporate Phone: 800-793-0093

See installation instructions for additional details.