ER30G

Revised 10/08/08

30” Wide, Epicure™

 

PLANNING

All Gas Range

2/2

GUIDE

All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.

B

Model Number

“A”

“B”

ER30G

30 1/16” (764mm)

30” (762mm) Minimum

36” (914mm) Recommended

 

 

Non-Combustible surface along back wall recommended

30” (762mm)

min.*

**

A

Suggested location of utilities***

*Vertical to combustible surface

**Cabinet depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimesions

***Consult local code for exact location requirements.

NOTES:

1.Utilities may be located in the lower left corner of the adjacent right cabinet. (Recommended)

2.Contact your local building department to verify compliance with local code interpretation.

Cutout dimensions

GAS SUPPLY PRESSURE REQUIREMENTS

Gas

Manifold

Min. Gas Supply

Max. Input

Type

Pressure* (WC)

Pressure (WC)

Pressure

Natural

5”

6”

1/2 p.s.i.

LP

10”

11”

1/2 p.s.i.

IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label on top of the kick plate below the door (remove the door according to the installation instructions to view it).

The gas connection is located on the back of the unit as shown.

121/2”

(31.8 cm)

to 14 5/8”

(37.1 cm)

2 5/8” (66.7 cm)

back of range

Web: http://www.Dacor.com

Specifications are subject to change without notice.

5.6

Corporate Phone: 800-793-0093

See installation instructions for additional details.