Installation Specifications

 

Installation Planning

 

 

 

◊ A qualified technician must complete the installation of this

 

 

 

built-in appliance. Proper installation is the responsibility of

 

 

 

the customer.

 

 

 

◊ Carefully check the installation location. The oven should be

 

 

 

placed for convenient access. Make certain that electrical

 

 

 

power can be provided in the selected location.

1 ¾” Min.

27"/30"/36"

 

◊ Plan the installation so that all minimum clearances are

(44mm)

Dacor

 

 

single oven

 

met or exceeded. Dimensions shown provide minimum

 

 

 

 

 

clearances, unless otherwise noted. Be certain that proper

 

 

 

clearance is provided for the oven door when it is in the open

 

 

 

position.

C

Warming Oven

 

 

 

◊ The specified minimum cabinet depth and width must be

D

 

120 Vac

provided. The cabinet depth and width must completely

 

electrical

enclose the recessed portion of the oven.

C

Warming Oven

outlets

◊ Cabinet cutout dimensions must be used as indicated. All

 

 

 

 

contact surfaces between the appliance and the cabinet must

 

 

 

be solid and level. The oven support platform must be flush

 

Toe Kick

 

with the bottom edge of the cabinet cutout.

5/8” Min.

A

 

 

 

◊ Make certain that you have everything necessary to ensure a

(16mm)

 

 

 

 

 

 

proper installation before proceeding.

 

 

 

NOTES:

Stacked Installation with Wall Oven

1.Minimum Cutout Depth:

Model IOWO24 - 20” (508mm)

All other models - 23 3/8” (594mm)

2.The IOWO24 and EWO36 models cannot be stacked.

3.The IOWO24 warming oven is not approved for installation under a wall oven.

 

“A” Cutout

“B” Min. Width

“C” Cutout

“D” Min. Gap

Model

to Adjacent

Width

Height

Between Cutouts

 

Doors/Drawers

 

 

 

 

IOWO24

22 9/16” (573mm)

N/A*

12 1/8” (308mm)

N/A*

IWO24

22 1/2” (572mm)

 

 

 

 

EWO24

24 1/4” (616mm)

 

 

 

 

 

EW27

 

27 1/4” (692mm)

 

1 1/16” (27mm)

EWO27

 

 

 

 

 

 

 

IWO27

 

N/A*

 

N/A*

MW27

 

 

 

 

MWO27

 

27 1/4” (692mm)

 

 

PW27

25 1/2” (648mm)

 

9 1/8” (232mm)

 

EW30

 

 

 

 

 

 

 

EWO30

 

 

 

1 1/16” (27mm)

 

 

 

 

 

MW30

 

30 1/4” (768mm)

 

 

 

 

 

 

MWO30

 

 

 

 

 

 

 

 

 

 

 

 

PW30

 

 

 

 

 

 

 

 

 

PWO30

 

 

 

 

 

 

 

 

 

EWO36

34 3/8” (873mm)

36 1/4” (921mm

 

3” (76mm)

* Depends on size of cabinet face installed.

Table 1: Cutouts Dimensions

4