IVS1, IVS2, IVSR1, IVSR2
Revised | Integrated Ventilation System |
| PLANNING | |
1/1 | GUIDE | |||
08/04/08 |
|
8" (203mm) round exhaust with back draft damper
| Electrical |
| Access |
| Holes |
21 1/4" |
|
(540mm) | 6" |
22 1/2" | (152mm) |
(572mm) | 11 1/16" |
| (281mm) |
| 12 1/4" |
| (311mm) |
IVS1/IVSR1 overall dimensions
C
L
C
L
8" Exhaust
IVS1/ivsR1 overall dimensions(Top View)
10" Round
2" (51mm)
13" (305mm)
21" (533mm)
8" (203mm)
8" (203mm) round exhausts
with back draft damper
|
| Electrical |
|
| Access |
|
| Holes |
33 1/4" |
|
|
(845mm) |
| 6" (152mm) |
34 1/2" |
| |
| 11 1/16" | |
(876mm) |
| |
|
| (281mm) |
|
| 12 1/4" |
|
| (311mm) |
IVS2/ivsR2 overall dimensions | ||
C | C | C |
L 6 1/2" | L | 6 1/2" L |
(165mm) |
| (165mm) |
|
| C |
|
| L |
8" Exhaust
IVS2/ivsR2 overall dimensions(Top View)
NOTES:
1.An internal blower is included with model IVS1 and IVS2. Blower Ratings: 1200CFM for IVS2 and 600CFM for IVS1.
2.Remote blower is required for IVSR1/IVSR2 models.
3.The ATD10 is sold seperately.
(For use with IVS2 and IVSR2)
| Dedicated Circuit | Maximum | Total | Approximate |
|
Model No. | Required | Duct Length | Connected Load | Shipping Weight | |
IVS1 |
|
| 0.2 kW (2 Amp) | 25 lbs. |
|
| 120 Vac, 60 Hz, | Maximum 60 |
|
|
|
IVSR1 | 0.2 kW (1.5 Amp)* | 21 lbs. |
| ||
15 Amp Min. grounded, | Equivalent |
| |||
|
|
|
| ||
IVS2 | 0.4 kW (3 Amp) | 38 lbs. |
| ||
dedicated circuit | Straight Feet |
| |||
IVSR2 |
|
| 0.2 kW (1.5 Amp)* | 29 lbs. |
|
|
|
|
|
|
|
*Does not include remote blower |
|
|
|
| |
Web: http://www.Dacor.com | Specifications are subject to change without notice. | 7.14 | |||