RGC304, RGC365
Revised 05/21/08
30”, 36” Wide, Preference™ PLANNING Renaissance Gas Cooktops 2/2 GUIDE
A
13" Max. | 18" Min. | |
(330 mm) | ||
(457 mm) | ||
|
30" Min.
(762 mm)
3 1/8" Min.
(79 mm)
All tolerances +1/16”
| 1/4” (6 mm) |
| Mimimum clearance |
| to combustible |
B | surfaces |
Under Cabinet Clearances
Model | B: Minimum |
|
|
RGC304 | 29” (737 mm) |
RGC365 | 35 ¼” (895 mm) |
Clearances to Combustibles
Model | A: Minimum | A: Recommended |
RGC304 | 30” (762 mm) | 36” (914 mm) |
RGC365 | 36” (914 mm) | 42” (1067 mm) |
Front of Unit
Data Label
Web: http://www.Dacor.com
Corporate Phone:
| RGC304 | RGC304LP | |
| RGC365 | RGC365LP | |
Total Connected | 0.25 Amps | 0.25 Amps | |
Load | (0.03 kW) | (0.03 kW) | |
Circuit | 120 Vac, | 120 Vac, | |
Requirement | 60 Hz, 15 Amp | 60 Hz, 15 Amp | |
Gas Type | Natural | LPG | |
Manifold | 5” Water Column | 10” Water Column | |
Pressure | |||
|
| ||
Min. Gas Supply | 6” Water Column | 11” Water Column | |
Pressure | |||
|
| ||
Power Cord | 40” (1016 mm) | 10” (254 mm) | |
Length | |||
|
| ||
Gas and Electrical Requirements* |
*The data above is for reference only. If the above data does not agree with the product data label, use the data on the product data label.
Specifications are subject to change without notice. | 4.12 |