Service manual WP 895/895F, CP885/885F
The vertical waveform can be scaled according to the average beam current. This is used to compensate the effects of electric
Reset of all VDP functions is performed by the RESQ pin. When this pin becomes active, all internal registers and counters are lost.
The VDP does not have a standby mode. To disable all the analogue and digital video functions, it is necessary to switch off the supplies for analogue
The TV controller basically consists of the CPU, RAM, ROM, and a number of peripheral modules. For instance:
–a memory banking module is included to allow access to more than 64 kB memory.
–a bootloader software is included to allow
The TV controller runs the complete software necessary to control a TV set. The software includes control of the audio, video, OSD, and text processors on chip, as well, as control of external devices like tuner or stereo decoder. Communication between the TV controller and external devices is done either via I 2 C bus interface or via program- mable port pins. The TV Controller is clocked with f OSC = f XTAL /2.
The CPU is fully compatible to WDC’s W65C02
- 49 -