Danby DAC 5209M manual Troubleshooting, Problem, Possible Cause, Solution

Models: DAC 5209M

1 20
Download 20 pages 9.05 Kb
Page 10
Image 10
TROUBLESHOOTING

TROUBLESHOOTING

Occasionally, a problem may occur that is minor, and a service call may not be necessary. Use this troubleshooting guide for a possible solution. If the unit continues to operate improperly, call an authorized service depot or Danby’s Toll Free Number for assistance:

1-800-26- 1-800-26-  (1-800-263-2629)PROBLEMPOSSIBLE CAUSESOLUTION (1-800-263-2629)

PROBLEM

POSSIBLE CAUSE

SOLUTION

• Air conditioner will not

• No power to the unit.

• Check connection of power cord

operate.

 

to power source

 

 

• Check fuse or circuit breaker

 

 

• Set SELECTOR SWITCH to

 

 

position other than “OFF”

 

 

• The power cord “RESET” button

 

 

must always be pushed in

 

 

(engaged) for correct operation.

• Inefficient or no cooling.

• Dirty air filter

• Clean/replace air filter

 

• Unit size inappropriate for

• Check with dealer to determine

 

application

proper unit capacity for application

 

• Blocked air flow

• Remove obstruction from grill or

 

 

outdoor louvres

 

• Power interruption, settings

• Turn the unit off and wait 5

 

changed too quickly, or

minutes before attempting to

 

compressor overload tripped.

restart.

• Noisy unit

• Loose parts

• Tighten loose parts

 

• Inadequate support

• Provide additional support to unit

• Odors

• Formation of mold, mildew, or

• Clean unit thoroughly

 

algae on wet surfaces.

• Place algaecide tablet in base pan

 

 

 

• Water dripping outside

• Hot and humid weather

• Condensation run-off is normal

 

 

under these conditions

• Water dripping inside

• Unit is not properly angled to

• Unit must be installed on an angle

 

allow water to drain outside

for proper condensation run-off.

 

 

Check the unit and make any

 

 

adjustments.

• Ice or frost build-up

• Low outside temperature

• When outdoor temperature is

 

 

approximately 18.3°C (65°F) or

 

 

below, frost may form when unit is

 

 

in cooling mode. Switch unit to FAN

 

 

(only) operation until frost melts.

 

• Unit air filter is dirty

• Remove and clean filter.

 

 

 

NOTES: 1) If circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a qualified technician

2)When unit is installed using proper installation steps, unit is properly tipped toward the outdoors to allow for condensation run-off.