Danby DPAC12010H Operation, Features Of The Control Panel Key Pad Functions, TEMPERATURE Adjust

Models: DPAC12010H

1 20
Download 20 pages 8.17 Kb
Page 6
Image 6
OPERATION

OPERATION

FEATURES OF

THE CONTROL

PANEL

KEY PAD FUNCTIONS

FEATURES OFPOWER SWITCH: Turns unit ON/OFF

AUTO-TIMERMODE: Allows you to scroll through and select desired operating mode.

NOTE: The time is adjustable between 1-24 hours.FAN: Select from three different fan settings; High, Medium, and Low.

TEMPERATURE Adjust:AUTO-TIMER

AUTO-TIMER Adjust:

Auto off- With machine in running mode, press timer button to set timer control. Press STATUS DISPLAYor Timer & Temp. Displaybuttons to select number of hours you would like the unit to run before it automatically shuts off.

Auto on- With machine in stand by mode, press timer button to set timer control. Press Timer Set or Dehumidify Modebuttons to select number of hours before the unit automatically starts running in air conditionning mode.

NOTE: The time is adjustable between 1-24 hours.

TEMPERATURE Adjust:

Used for adjusting the thermostat.

The default display is room temperature.

In cooling mode, when Fan ModeHeating Modebutton is pressed, the set temperature is displayed and may be adjusted. After 15 seconds the display will revert back to room temperature. Temperature is only adjustable in cool mode.

NOTE: By pressing both FAN SPEED INDICATOR LIGHTSbuttons at the same time for more than 3 seconds, the display will toggle between Celsius and Fahrenheit.

STATUS DISPLAY

Low FanWarning Light

Condensed water may accumulate in the unit. If the internal tank becomes full, the Warning signal in the LCD Display will light up and the unit will not operate until the unit has been drained.

Manual backgroundTimer & Temp. Display

Room Temp.

Manual backgroundTemp. Set

Manual backgroundTimer Set

MODE INDICATOR LIGHTS

Cooling Mode

When cool mode is selected, the indicator light will shine GREEN. During the cooling mode, the air is cooled and hot air is exhausted outside through the exhaust tube. Adjust fan speed to suit your desired comfort level.

Note: The air exchange h ose must vent outside the room when using cool mode.

Manual backgroundDehumidify Mode

When dehumidify mode is selected, the indicator light will shine ORANGE. Air is dehumidified as it passes through the unit, without being in full cooling mode. The fan will operate on med. speed. If room temperature is >25°C (77°F), fan speed can be adjusted; otherwise fan speed is fixed to “low”.

Note: The warm air exchange hose must vent inside the room when using Dehumidify Mode, not outside as it does when cooling. If the unit is vented outside, some cooling will occur.

Manual backgroundFan Mode

When fan mode is selected, the indicator will shine YELLOW. Air is circulated throughout the room with no cooling.

Note: The unit does not need to be vented in Fan mode.

Manual backgroundHeating Mode

When heating mode is selected the indicator will shine RED. Heating is activated only when the ambient temperature is below 25°C (77°F).

FAN SPEED INDICATOR LIGHTS

Manual backgroundHigh Fan

Manual backgroundMedium Fan

Manual backgroundLow Fan

NOTE: After switching the air conditioner off, you must wait 3 minutes before switching it back on again.

5

Page 6
Image 6