INSTALLATION

ELECTRIC SHOCK HAZARD: To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.

Caution: To avoid installation/operation difficulties, read these instructions thoroughly.

Flexible Exhaust Hose (13cm) & Exhaust nozzle connector (2 pcs)... from 17 7/10 (45cm) to 53 1/6” (135cm)

Flexible Exhaust Hose (11cm) & Exhaust nozzle connector (2pcs)...from 15 3/4” (40cm) to 51 1/5” (130cm) Adjustable window door slider kit (3 pcs)... from 28 1/3”(72cm) to 80” (203cm)

Fixture..... (2 pcs) & Screws..... (8 pcs)

NOTE: The exhaust/window kit must be installed at all times when the unit is operating under AIR CONDITIONING mode. There should be at least 11.8” (30cm) clearance between the unit and any other objects or building structures, and should be installed on a level surface.

Fig. 1 INSTALLATION ACCESSORIES

 

 

Flexible Exhaust Hose

 

 

 

 

 

Fixture

Exhaust Nozzle

 

 

 

 

 

 

 

 

Connector

 

 

 

 

 

 

 

 

 

 

 

 

Screws

Adjustable Window Slider Kit: 28 1/3” (72cm)- 80” (203cm)

Water hose (79”/ 200cm)

Instructions for Assembling the Window Kit- Fig. 2

1)Insert tube adapters through the back of the window panel.

2)Secure each tube adapter with four screws through the front of the window panel.

3)Insert window panel extensions into window panel. Lightly tighten the screws in the window panel to hold the extensions in place.

Fig. 2

 

 

Back of window panel

Tube Adapters

WINDOW KIT

INSTALLATION

Air Conditioning Mode ONLY: Your window kit has been designed to fit most standard “vertical”/ ”horizontal” windows up to a maximum height of 80” (203cm). For vertical window applications, multi lock positions are provided on the edge of each slider section to secure each sliding section together.

1)Select a suitable location, making sure you have access to an electrical outlet.

2)Install the flexible hose to the rear side of the unit. Insert the hose collar on top of the exhaust opening and twist to lock into position.

3)Install the adjustable Window Slider Kit as required (see Fig. 4a & 4b).

4)Install the opposite end of the flexible exhaust hose into the window exhaust adapter.

5)Install the window exhaust adapter into the opening in the slider section, making sure the window slider sections are secure.

6)Plug the unit into a 115V/60Hz grounded electrical outlet.

 

 

 

 

 

 

 

 

 

 

 

 

Fig 3a

 

 

Fig 3b

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal Window

 

 

 

Window Slider

 

 

 

 

 

 

 

 

 

Kit:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min.: 28 1/3

 

 

 

 

 

 

 

Vertical

 

(72cm)

 

 

 

 

 

 

 

Window

 

Max.: 80”

 

 

 

 

 

 

 

 

 

(203cm)

 

 

 

Window Slider Kit:

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

Min.: 28 /3” (67.5cm)

 

 

 

 

 

Max.: 80” (203cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Page 5
Image 5
Danby DPAC5009 manual Instructions for Assembling the Window Kit- Fig, Window KIT Installation