Danby DPAC 12099 operating instructions OPERATING INSTRUCTIONS cont’d, Dehumidifier

Models: DPAC 12099

1 22
Download 22 pages 36.55 Kb
Page 8
Image 8
OPERATING INSTRUCTIONS (cont’d)

OPERATING INSTRUCTIONS (cont’d)

AIR CONDITIONING IMPORTANT: The exhaust hose must be properly vented (outdoors) during air conditioning mode.

1)Press the POWER SWITCH key (Fig. A) to switch on the unit, and the previous set temperature will be shown in the temperature display area of the control panel.

2)Press the MODE key (Fig. B) until the COOL indicator light illuminates on the control panel (Fig.C). Each depression of the MODE key will advance to a different mode setting (Cool-Dehumidifier-Fan-Heat-Auto)

3)Press the appropriate increase DEHUMIDIFIER or decrease Manual background buttons (Fig. D) to select a suitable operating temperature setting. Temperature settings are adjustable between 16°C (61°F) to 32°C (89°F).

4)Press the FAN key (Fig. E) to select the desired fan speed setting (Auto-High- Med.-Low). Your selection will appear on the control panel (each depression of the fan key will advance to a different setting).

• Cooling stops automatically when the set temperature is achieved. Cooling resumes when the room temp. rises above the “set” temperature level.

Fig. A

Fig. B

Fig. D

Fig. E

Fig. F

High

Medium

Low

Fig. C

Green

Fig. G

DEHUMIDIFIER

Note: During dehumidifier mode, the exhaust hose does not

 

 

have to be vented outdoors.

 

 

 

 

 

 

 

 

Orange

 

1) Press the ON/OFF key pad to switch the unit on (Fig. A)

 

 

 

 

 

 

 

 

2) Press the MODE key (Fig. B) until the DRY indicator illuminates on the

 

 

 

 

 

control panel (Fig.G). Each press of the MODE key will advance to a different

 

 

 

 

 

mode setting (Cool-Dehumidifier-Fan-Heat-Auto).

 

 

 

 

 

3) If room temperature is >25°C (77°F), fan speed can be adjusted. Press the

 

 

 

 

Fig. H

 

 

FAN key (Fig. E) to select the desired FAN SPEED setting. Your selection will

 

 

 

 

 

 

 

 

 

 

appear on the control. Each depression of the fan key will advance to a

 

 

 

 

 

different fan speed as shown in Fig. F. Otherwise fan speed is fixed to “low”.

 

 

 

 

 

NOTE: The warm air exchange hoses must vent inside the room when using

 

 

 

 

 

Dehumidify Mode, not outside as in Cooling Mode.

 

 

 

 

 

 

 

 

 

 

 

 

FAN

NOTE: During Fan Mode, the exhaust hose does not have to be

 

vented outdoors.

1)Press the POWER SWITCH key to turn the unit on (Fig. H).

2)Press the MODE key (Fig. I) until the FAN indicator illuminates on the control panel (Fig. J). Each press of the MODE key will advance to a different mode setting (Cool-Dehumidifier-Fan-Heat-Auto).

3)Press the FAN Key (Fig. K) to select the desired FAN SPEED setting. Your selection will appear on the control panel. Each press of the fan key will advance to a different fan speed (High- Med- Low) as shown in Fig. L.

Fig. I

Fig. J

Fig. K

Fig. L

Yellow

High

Medium

Low

7

Page 8
Image 8