DX8200A-3002 QUICK GUIDE
4
Two 17-pin connectors provide access to the scanner’s local Lonworks network used for both input and output
connections to build a multi-sided or omni-station system.
17-pin Lonworks Connector Pinout
Pin Name Function
A1 GND Supply voltage (negative pin)
A2 VS Supply voltage 20 to 30 Vdc (positive pin)
Cable shield A - internally connected by
1 CHASSIS capacitor to chassis
2 n.c. Not connected
Cable shield B - internally connected by
3 CHASSIS capacitor to chassis
4 TXAUX Transmit data of auxiliary RS232
(referred to SGND)
5 SGND Signal ground (connected to GND)
6 RXAUX Receive data of auxiliary RS232
(referred to SGND)
7 VS_I/O Supply voltage of I/O circuit
8 Lon A+ Lonworks a line (positive pin)
9 Lon A- Lonworks a line (negative pin)
10 Lon B+ Lonworks b line (positive pin)
11 Lon B- Lonworks b line (negative pin)
12 SYS_I/O System signal
13 SYS_ENC_I/O System signal
14 Reserved Internally connected
15 Ref_I/O Reference voltage of I/O circuit
A1 A2
1
15
Female - Output
A1 A2
1
15
Male - Input
17-pin Local Lonworks Connectors