Dayton Operating Instructions and Parts Manual

3VH18A and 3VH19A

Dayton® Propane and Natural Gas

Construction Heaters

Installation (Continued)

4.Open natural gas supply valve slowly.

5.Check all connections for leaks.

Never use an open flame to check for

a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak that must be corrected. Correct all leaks at once.

6. Close natural gas supply valve.

Operation

Review and understand the

warnings in the General Safety Infor- mation section. They are needed to safely operate this heater. Follow all local codes when using this heater.

TO START HEATER

1.Follow all installation, ventilation, and safety information.

2.Locate heater on stable and level surface. Make sure strong drafts do not blow on heater.

3.Make sure unit is turned off by lightly depressing and turning control knob fully clockwise to OFF.

4.Open gas supply valve on gas supply slowly.

NOTE: If not opened slowly, excess-flow check valve on propane tank may stop gas flow. If this happens, you may hear a click inside the regulator assembly. This is the check valve closing. To reset the excess flow check valve, close propane supply valve and open it again slowly.

5.Slightly depress and turn control knob counterclockwise to the low position (See Figure 6 or 7).

Continue Turning Knob

Counterclockwise to

MED and HIStart

Off /Low

Position Position

Piezo

MEDIUM

START/

MEDIUM

START/

Ignitor

LOW

LOW

HIGH

OFF

HIGH

OFF

Button

 

 

 

 

Control

Knob

Figure 6 - Control Knob and Piezo Ignitor Button Locations for Propane Model 3VH18A

Piezo

 

Start

Ignitor

Off

Button

/Low

 

Position Position

 

START/

START/

 

MEDIUM LOW

MEDIUM LOW

 

OFF

OFF

 

HIGH

HIGH

Control

Knob

Figure 7 - Control Knob and Piezo Ignitor Button Locations for Natural Gas Model 3VH19A

6.With the control knob pushed all the way in, press and release the piezo ignitor button. Keep pressing ignitor button until the burner lights. Hold control knob down for a maximum of 15 seconds while attempting ignition. If heater does not ignite, release control knob and wait 3 minutes before attempting reignition.

NOTE: Keep hands and face away from outlet (around top of shell) of heater while attempting to start heater.

7.After ignition, hold control knob down for approximately 30 seconds. This activates the automatic control system.

8.When burner remains lit, set heater at the desired heat level by slightly depressing the control knob and turning counterclockwise to the Medium or High settings (See Figure 6 or 7).

9.If burner goes out, turn off gas. Slightly depress and turn control knob fully clockwise to OFF. For propane model, check for adequate fuel supply. Restart heater beginning at Step #1.

Running heater below specified

input rating may cause flashback. During flashback, the burner flame is mostly yellow. The flame will burn inside the burner tube, causing a roaring noise. If flashback occurs, turn heater off. After burner tube cools, restart the heater.

6

Page 6
Image 6
Dayton 3VH19A, 3VH18A instruction manual Operation, To Start Heater

3VH19A, 3VH18A specifications

Dayton 3VH18A and 3VH19A are advanced ventilation systems designed to meet the needs of various industrial and commercial applications. Both units are part of a series that prioritizes energy efficiency, reliability, and versatile performance, making them suitable for everything from warehouses to manufacturing facilities.

The Dayton 3VH18A is a direct drive fan with a robust motor that operates at a speed of 1,050 RPM, providing an airflow capacity of approximately 1,400 CFM. Its simple yet effective design enables effective air circulation, ensuring that spaces are adequately ventilated. The fan is equipped with a lightweight but durable metal housing, which can withstand the rigors of continuous operation.

In comparison, the Dayton 3VH19A features a slightly higher airflow capacity of 2,300 CFM, making it ideal for larger spaces. This fan also operates at 1,050 RPM, but its larger diameter impeller allows it to push a greater volume of air, enhancing its efficiency. Both models incorporate high-quality ball bearings, promoting longevity and low maintenance needs.

One of the standout technologies of both 3VH18A and 3VH19A is their energy efficiency. The fans are designed to minimize power consumption while maximizing airflow, resulting in lower operational costs for end-users. They also adhere to stringent industry standards for efficiency and safety, making them a reliable choice for various applications.

Another feature is their versatility in installation options. Both units can be mounted on walls or ceilings, allowing for flexible positioning depending on the specific ventilation requirements of a space. Additionally, they are compatible with various control systems, enabling users to integrate them seamlessly into existing HVAC systems for optimized climate control.

In terms of noise levels, both the Dayton 3VH18A and 3VH19A operate quietly, which is essential in environments where noise reduction is a priority, such as schools and healthcare facilities. This focus on low noise output contributes to a more comfortable environment for occupants and workers.

Overall, Dayton 3VH18A and 3VH19A models stand out due to their combination of powerful airflow, energy efficiency, and quiet operation. These features make them valuable assets for enhancing indoor air quality and ensuring comfort in a range of settings. Whether for industrial use or commercial applications, these ventilation systems fulfill the vital role of effective air management, contributing to healthier environments.