Versa Drawer™ Refrigeration Units

STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT UNDER WARRANTY

Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.

A maximum of 1-hour is allowed to diagnose a defective component.

A maximum of 1-hour is allowed for retrieval of parts not in stock.

A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.

Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work Authorization from Delfield. You must submit the number with the service claim.

LABOR OF 1 HOUR IS ALLOWED TO REPLACE:

Solenoid Coil

Hi-limit/Thermal Protector Switch

Compressor Start Components and Overload Protector

LABOR OF 2 HOURS TO REPLACE:

Drawer Tracks/Cartridges

Pressure Control

Microprocessor Control

LABOR OF 3 HOURS TO REPLACE:

• Expansion Valve

LABOR OF 4 HOURS TO REPLACE:

Compressor

This includes recovery of refrigerant and leak check.

$55.00 (USD) maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings, solder, brazing rod, nitrogen, or similar fees.)

Evaporator/Condenser Fan Motor and Blade

Door Hinges, Locks, and Gaskets

Solenoid Valve

Locate/Repair Leak

Condenser or Evaporator Coil

Refrigerants

R404A A maximum of $16.00/lb.(0.43kg) (USD).

Delfield · 980 S. Isabella Road, Mt. Pleasant, MI 48858 · (989) 773-7981 or (800) 733-8829 · Fax (989) 773-3210

16

Page 17
Image 17
Delfield 18600VD manual Labor of 1 Hour is Allowed to Replace, Labor of 2 Hours to Replace, Labor of 3 Hours to Replace