Installation

Safe Chill™ Blast Chillers Service & Installation Manual

Installation

Location

Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. Reinforce the floor if necessary to provide for maximum loading.

For the most efficient operation, be sure to provide good air circulation inside and out.

Inside cabinet: Do not pack the equipment so full that air cannot circulate.

Outside cabinet: Be sure that the unit has access to ample air. Avoid hot corners and locations near stoves and ovens.

Installation note: Evaporator drains are also located to the right of the evaporator housing and run to a condensate evaporator pan. No external drains are needed as this is all self contained. Drain lines need to be kept free from obstruction to allow for proper water removal.

It is recommended that the unit be installed no closer than 2” from any wall.

Leveling

A level cabinet looks better and will perform more efficiently when the doors line up with the door frames properly, the cabinet will not be subject to undue strain, and the corners of the shelves will not move around on the supports. Use a level to make sure the unit is level from front to back and side to side.

The unit comes standard with non adjustable casters, a level floor is very important. If it becomes necessary to level the unit adjustable legs are available.

Stabilizing

All models are supplied on casters for your convenience, ease of cleaning and mobility. It is very important, however, that the cabinet be installed in a stable condition with the front wheels locked while in use.

Should it become necessary to lay the unit on its side or back for any reason, allow at least 24 hours before start-up so as to allow compressor oil to flow back to the sump.

Electrical Connection

Refer to the amperage data on page 2, the serial tag, your local code or the National Electrical Code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must be run for connection of the line cord, or permanent connection to the unit.

The unit should be disconnected from the power source whenever performing service, maintenance functions or cleaning the refrigerated area.

Be careful - the line cord is not run over by the casters when moving the unit. This can damage the cord.

Operation Information

(SEE PAGE 4 FOR DIAGRAM OF CONTROL PANEL)

Operating Pressures

Normal operating pressures should be achieved during the preservation mode, with approximately 75 of ambient temperature. Freezer mode 15# suction and 220# discharge. Chilling mode 55# suction and 220# discharge.

Blast Chilling (soft mode): This mode pulls the food down from the starting temperature to food set point of 37˚F (FP1). Once the temperature is obtained the unit sounds an alarm and either switches to preservation mode automatically (after the alarm times out) or manually. During pull down in soft mode, the blast chiller maintains a box temperature of 23˚F (BT1). This mode is primarily used for pulling down delicate foods.

Blast Chilling (hard mode): This mode operates the same way as the soft mode except for the box temperature. During pull down from start until one of the two food probes reaches 47˚F (FP2) the box temperature is maintained at -5˚F (BT2), after this point the box temperature is held at 23˚F (BT1) until the food reaches 37˚F (FP1). This mode is for items that are harder to pull down or if a faster chilling time is desired.

Blast Chilling (timed mode): This mode operates in either a soft or hard mode. The user can preset the amount of time the chiller pulls down for up to 240 minutes (TC1). The unit will pull down until the time is reached or the two probes hit 37˚F (FP1). At this point the unit will sound an alarm and go into preservation mode.

Freezer Mode: This mode pulls the food down from starting point to 0˚F (FP3). In this mode the unit operates in a hard chill mode until one of the two food probes reach 37˚F (FP1). At that point the box temperature is pulled down to -25˚F (BT3) until the food set point of 0˚F (FP3) is reached. At this point an alarm is sounded and the unit can go into preservation mode.

Preservation Mode: After any of the above cycles reach their set point, the unit will go into a preservation mode. This mode will be held until the user terminates it. After chilling, the food probes will maintain a temperature of 37˚F (FP1) using a box temperature of 23˚F (BT1). After the freezing, the food probes will maintain a temperature of 0˚F (FP3) using a box temperature of -15˚F (BT3).

continued pg. 4