Project __________________________
Item ____________________________
Quantity _________________________
| CSI Section 11400 |
| |
|
Refrigerator/Freezer Combination Module, 34” height, 35” depth
MODELS
❑
SPRF-W SHELLEYSPEED™
134a
REFRIGERANT
STANDARD FEATURES
•14-gauge stainless steel top standard
•34” counter height, 35” depth
•Two separate systems, one section refrigerator and one section freezer
•9’ long cord and plug are supplied standard
•
•Electrical: 120 volt, 60 cycle, single phase
•R134A
•Removable sliding lids (two per unit) standard
•Standard on 5” diameter polyurethane swivel casters
•Stainless steel fully retractable interlock provided as standard
•Basket rack system is standard
•A wide selection of laminate colors available at no additional charge
•Laminate selection has
•Meets NSF2, NSF7, UL and CEC standards
•
•Holds baskets size, 13.25” x 26.13” x 2.5” or 13.25” x 26.13” 4.75”
OPTIONS AND ACCESSORIES
❑Single tier merchandiser (Unheated)
❑Double tier merchandiser (Unheated)
❑16”x35” Stainless steel drop tray shelf
❑Stainless steel cash shelf
❑Tray slides
•
•Tubular bar
❑2” Wire basket (13.25”x26.13”x2.5”)
❑4” Wire basket (13.25”x26.13”x4.75”)
❑Decal package
❑Canopy
REFRIGERATOR/FREEZER
SPECIFICATIONS
Exterior: Exterior body is constructed of
Exterior top is constructed of
Interior, Refrigerated Section: Refrigerated cold pan is 14” deep
On/Off switch is located on the operator side in a recessed panel with a hinged cover plate. Refrigerated tank maintains NSF7 temperature requirements.
Interior, Freezer Section: Freezer cold pan is 13” deep
On/Off switch is located on the operator side in a recessed panel with a hinged cover plate. Freezer tank maintains 0˚ to
Lid: Lids are constructed of stainless steel and are foamed with polyurethane insulation. The lid thickness is 3/4”. Lid handle shall be black, recessed ABS. Lids are removable without the use of tools.
Stainless steel lid locking bar is standard. Bar has locking handle at one end and mounts to clips, which are bolted to the top of the cabinet. The locking bar extends the length of the unit. Entire assembly can be removed during the serving period.
Refrigeration Section: Refrigeration system uses R134A refrigerant and has a
The system utilizes and evaporator coil and fan package for
Freezer Section: Refrigeration system uses R404A refrigerant and has a
Electrical: Electrical connections shall be 120 volt, 60 Hertz, single phase. Unit shall have a 9’ long electrical cord and NEMA
Casters: Unit is mounted on 5” (12.7cm) diameter swivel polyurethane casters with
Styling: Units are standard with
MODULE, 34”HEIGHT, 35” DEPTH
980 S. Isabella Road | Phone: | Approval _________________ | |
Mt. Pleasant, MI 48858 | Fax: | Date____________________ | |