Environmental

NOTE: For additional information about environmental measurements for specific system configurations, see www.dell.com/environmental_datasheets.

Temperature

 

Operating

10° to 35°C (50° to 95°F) with a maximum

 

temperature gradation of 10°C per hour

 

NOTE: For altitudes above 2950 feet, the maximum

 

operating temperature is derated 1ºF/550 ft.

Storage

–40° to 65°C (–40° to 149°F) with a maximum

 

temperature gradation of 20°C per hour

Relative humidity

 

Operating

20% to 80% (noncondensing) with a maximum

 

humidity gradation of 10% per hour

Storage

5% to 95% (noncondensing) with a maximum

 

humidity gradation of 10% per hour

Maximum vibration

 

Operating

0.26 Grms at 5–350 Hz in operational

 

orientations

Storage

1.54 Grms at 10–250 Hz in all orientations

Maximum shock

 

Operating

One shock pulse in the positive z axis (one pulse

 

on each side of the system) of 31 G for 2.6 ms

 

in the operational orientation

Storage

Six consecutively executed shock pulses in the

 

positive and negative x, y, and z axes (one pulse

 

on each side of the system) of 71 G for up to 2 ms

Altitude

 

Operating

–16 to 3048 m (–50 to 10,000 ft)

 

NOTE: For altitudes above 2950 feet, the maximum

 

operating temperature is derated 1ºF/550 ft.

Storage

–16 to 10,600 m (–50 to 35,000 ft)

Getting Started With Your System