Dell R720XD manual Relative humidity, Maximum vibration, Maximum shock, Environmental

Models: R720XD R720

1 11
Download 11 pages 39.53 Kb
Page 10
Image 10
support.dell.com/manuals.

Environmental

 

°C max dew point. De-rate maximum

 

allowable dry bulb temperature at 1

 

°C/300 m above 900 m (1 °F per 550 ft).

 

NOTE: When using PowerEdge R720

 

with internal GPGPU card(s), the

 

continuous operation range is 10 °C to

 

30 °C at 10% to 80% RH, with 26 °C

 

max dew point.

 

NOTE: For information on supported

 

expanded operating temperature

 

range and configurations, see

 

support.dell.com/manuals.

Storage

–40 °C to 65 °C (–40 °F to 149 °F) with a

 

maximum temperature gradation of 20 °C

 

per hour

Relative humidity

 

Operating

20% to 80% (noncondensing) at a

 

maximum wet bulb temperature of 29 °C

 

(84.2 °F)

Storage

5% to 95% at a maximum wet bulb

 

temperature of 38 °C (100.4 °F)

Maximum vibration

 

Operating

0.26 Grms at 5–350 Hz (all operation

 

orientations)

Storage

1.87 Grms at 10–500 Hz for 15 min (all six

 

sides tested)

Maximum shock

 

Operating

One shock pulse in the positive z axis

 

(one pulse on each side of the system) of

 

31 G for 2.6 ms in the operational

 

orientation

Storage

Six consecutively executed shock pulses

 

in the positive and negative x, y, and z

10