
Item Name Icon Description
•On steady amber: Hardware detected fault
•Blinking amber: Software detected fault
3 Identification
button
Lights when the storage system identification is enabled.
•Off: Normal status
•Blinking blue: Storage system identification enabled
4 Unit ID display — Displays the storage system identification number (01).
5 Hard drives — Up to 12 3.5–inch or 24 2.5–inch SAS hard drives
SCv2000/SCv2020 Back-Panel Features and IndicatorsThe back panel of the SCv2000/SCv2020 shows the storage controller indicators and power supply
indicators.
Figure 7. SCv2000/SCv2020 Back Panel View
Item Name Icon Description
1 Power supply/
cooling fan module
(PSU) (2)
— Contains a 580 W power supply and fans that provide cooling
for the storage system.
2 Battery backup unit
(BBU) (2)
— Allows the storage controller to shut down gracefully when a
loss of AC power is detected.
3 Storage controller
(1 or 2)
— Each storage controller module contains:
•Back-end ports: Two 6 Gbps SAS ports
•Front-end ports: Fibre Channel ports, iSCSI ports, or SAS
ports
•MGMT port: Embedded Ethernet/iSCSI port, which is
typically used for system management
NOTE: The MGMT port can share iSCSI traffic if the
Flex Port license is installed.
16 About the SCv2000/SCv2020 Storage System