Table
PowerEdge | Riser Board Option | RAID adapter | PCI Slot Assignment |
System |
|
|
|
|
|
|
|
4600 | N/A | PERC 4/DC | Any available PCI or |
|
|
|
|
6600 | N/A | PERC 4/DC | Any available PCI or |
|
|
|
|
6650 | N/A | PERC 4/DC | Any available PCI or |
|
|
|
|
6800 | N/A | PERC 4/DC | |
|
| PERC 4e/DC | PCIe slot 1, 3, 4, or 5. |
|
|
|
|
6850 | N/A | PERC 4/DC | |
|
| PERC 4e/DC | PCIe slot 1, 3, 4, or 5. |
NOTE: It is recommended that the RAID adapters be placed on separate buses to balance the load on the system. These buses are identified as separate rows in Table
Installing the PERC Adapter
You must install the PERC 4/DC card in a
You must install the PERC 4e/DC adapter in a PCIe slot. See the I/O slot assignments in Table
Ensure that your system has the correct PERC firmware and Windows driver. See the "Dell Cluster Configuration Support Matrix" for the supported PERC driver and firmware versions. To verify your driver, perform the following steps:
1Click Start, point to Programs→ Administrative Tools and click Computer Management.
2 In the Computer Management window, point to System Tools→ Device Manager, and click the plus sign (+) to expand SCSI and RAID controllers. One or more PERC adapters are listed.
3In the Device Manager window,
See your PERC RAID adapter documentation for information about downloading the latest firmware.
Obtaining More Information
See the section related to your cluster product for more information on supported configurations.
See the Dell PowerEdge Cluster SE500W Installation and Troubleshooting Guide for a detailed list of related documentation.
Platform Guide
9