Environmental
Maximum vibration
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations)
Non-operating 2.2 Grms at 5 Hz to 500 Hz for 15 min (all six sides tested)
Maximum shock
Operating One shock pulse (all operating orientations) of 40 G for 2 ms in the
operational orientation
Non-operating Six consecutively executed shock pulses in the positive and negative x,
y, and z axes (one pulse on each side of the system) of 71 G/2 ms half
sine shock
Six consecutively executed shock pulses in the positive and negative x,
y, and z axes (one pulse on each side of the system) of 50 G/320 inps
long duration half sine shock
Altitude
Operating –15.2 m to 3048 m (–50 to 10,000 ft)
NOTE: In compliance with the requirements of the official Chinese
standards, the operating altitude for systems shipping in China is
in the range of –15.2 m to 5000 m (–50 ft to 16400 ft).
NOTE: For altitudes above 2950 ft, the maximum operating
temperature is derated 1 ºF/550 ft.
Storage –15.2 m to 10,668 m (–50 ft to 35,000 ft)
Airborne Contaminant Level
Class G1 as defined by ISA-S71.04-1985