Environmental
Operating | 10% to 80% relative humidity (RH), with 26 °C maximum |
| dew point. |
Storage | 5% to 95% relative humidity ambient with 33 °C (91 °F) |
| maximum dew point. |
Maximum vibration |
|
Operating | 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). |
Storage | 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides |
| tested). |
Maximum shock |
|
Operating | One shock pulse in the positive z axis (one pulse on each |
| side of the system) of 31 G for 2.6 ms in the operational |
| orientation. |
Storage | Six consecutively executed shock pulses in the positive |
| and negative x, y, and z axes (one pulse on each side of |
| the system) of 71 G for up to 2 ms. |
| Six consecutively executed shock pulses in the positive |
| and negative x, y, and z axes (one pulse on each side of |
| the system) of 22 G faired square wave pulse with |
| velocity change at 200 inches/second (508 centimeters/ |
| second). |
Altitude |
|
Operating | |
| NOTE: For altitudes above 2950 ft, the maximum |
| operating temperature is derated 1 ºF/550 ft. |
Storage | |
Airborne contaminant level |
|
Class | G1 as defined by |
9