Environmental

Maximum vibration

Operating

0.26 Grms at 5 Hz to 350 Hz (all operation

 

orientations).

Storage

1.87 Grms at 10 Hz to 500 Hz for 15 min (all

 

six sides tested).

Maximum shock

 

Operating

One shock pulse in the positive z axis

 

(one pulse on each side of the system) of

 

31 G for 2.6 ms in the operational

 

orientation.

Storage

Six consecutively executed shock pulses

 

in the positive and negative x, y, and z

 

axes (one pulse on each side of the

 

system) of 71 G for up to 2 ms.

 

Six consecutively executed shock pulses

 

in the positive and negative x, y, and z

 

axes (one pulse on each side of the

 

system) of 22 G faired square wave pulse

 

with velocity change at 200 inches/

 

second (508 centimeters/second).

Altitude

 

Operating

–15.2 m to 3048 m (–50 ft to 10,000 ft).

 

NOTE: In compliance with the

 

requirements of the official Chinese

 

standards, the operating altitude for

 

systems shipping in China is in the

 

range of –15.2 m to 2000 m (–50 ft to

 

6560 ft).

 

NOTE: For altitudes above 2950 ft, the

 

maximum operating temperature is

 

derated 1 ºF/550 ft.

Storage

–15.2 m to 10,668 m (–50 ft to 35,000 ft)

Airborne contaminant level

 

Class

G1 as defined by ISA-S71.04-1985