Position the appliance in the room to be dehumidified.

A free space of at least 50 cm must be left at the front of the dehumidifier, so as not to block the air outlet. For efficient ventilation a space of about 5-10 cm should be left at the back of the appliance.

The condensate can be drained in one of the following ways:

A)Draining into the tank

The condensate can be drained directly into the tank (fig. 1)

The tank can be easily removed and has a handle making it simple to carry and empty (fig. 1).

fig. 1

B)Continuous external draining

If the appliance is to be operated for long periods but you are unable to empty the tank regularly, you are recommended to use the continuous drain facility.

1)Drill the inside of the drain spout using a narrow drill bit. (Fig. 2)

2)Fasten the rubber hose to the spout. For models without drain hoses supplied, we sug- gest you purchase a rubber hose around 2m long, with an internal diameter of 9.5 mm.

3)Make sure that the hose is not higher than the spout In caso contrario l’acqua resterà nella tanica; verificare inoltre che il tubo non sia strozzato (Fig. 3). or water could remain in the tank. Check the hose is not choked (Fig. 3).

N.B.: Keep the rubber bung. You will need it to plug the hose or close the spout if you revert to draining into the tank. (see point A).