GB 10-05-2001 9:00 Pagina 5

If Maximum power has been selected, adjust the thermostat dial (Fig. 1) to the desired comfort temperature, from 42° and 95° F (5°C to 35°C). By turning the thermostat dial the display will show the selected temperature.

In addition, the smaller characters on the right-hand side of the display will indicate the actual room temperature (see figure).

selected temperature

MAN°F

room temperature

 

This heater has Electronic Climate Control which automatically monitors and selects the ideal power setting to maintain your chosen temperature.

If the selected temperature is higher than the actual room temperature, the appliance will start automatically and rapidly heat the room until it reaches the selected temperature. The unit will automatically maintain the temperature at a constant level, by switching between maximum, medium and minimum power.

If the room temperature exceeds the selected temperature level, the appliance will switch off. The appliance will switch on automatically again when the room temperature falls below the selected temperature level.

If medium power level has been selected using the “ON MODE” button, the appliance will modulate between medium and minimum power to maintain a selected temperature.

3) ANTIFREEZE FUNCTION

Press the “ON MODE” button to select the “P max” power level.

Set the thermostat dial to the “*” position (Fig. 1). The display will show 42°F (see figure). When set in this way, the appliance will switch on automatically only if the room temperature falls below 42°F (5°C), to prevent it from freezing, at minimum energy consumption.

The display will show “LO” (see figure).

This function is not guaranteed in the event of black outs, even if lasting just a few seconds.

AMMAN

5

Page 5
Image 5
DeLonghi Fan Heater manual Antifreeze Function