Delta Three phase 20-120kVA, NH Plus series, Technical Specifications, Model, NHP20, NHP40

Models: 20-120kVA

1 2
Download 2 pages 6.9 Kb
Page 2
Image 2
Three phase 20-120kVA

NH Plus series

Three phase 20-120kVA

Technical Specifications

 

Model

 

NHP20
NHP40

 

NHP60

 

 

NHP80
NHP100
NHP120

 

 

 

 

 

 

Power Rating – kVA

 

20

40

 

60

 

80

100

120

 

Power Rating - kW

 

16

32

 

48

 

64

80

96

 

Rating Voltage

 

V

 

380/220 , 400/230 , 415/240 (3phase, 4-wire plus ground)

 

Input

Voltage Range

 

V

 

208~477(line-line) / 120~276 (line-neutral) *

 

Input Current Harmonic

 

 

 

< 3 (full load)

 

 

 

 

 

 

 

 

 

Power Factor

 

 

 

 

 

 

> 0.99

 

 

 

Frequency

 

Hz

 

 

 

50 or 60 ± 5

 

 

 

Voltage

 

V

 

380/220 , 400/230 , 415/240 (3phase, 4-wire plus ground)

 

 

Voltage Harmonic

 

 

 

< 3 (linear load)

 

 

Output

Voltage Regulation

 

Static : ± 1 ; Dynamic : ± 7 (10% ~ 90% linear load)

 

Frequency

 

Hz

 

 

 

 

50 or 60

 

 

 

 

 

 

 

 

 

 

 

Frequency Regulation

Hz

 

 

 

± 0.05 (interior oscillator)

 

 

 

Hz

 

 

 

± 5 (synchronized), adjustable

 

 

 

 

 

 

 

 

 

 

 

 

Overload

 

 

 

 

≤125% : 10m inutes ; ≤150% : 1minute

 

Display

LED

 

 

 

UPS status : NormalBypassBackupFault

 

LCD

 

 

Input/OutputBypassInverterFrequencyLoading and battery voltageCurrent

 

 

 

 

 

 

 

 

 

 

 

UPS abnormal message and intelligent self diagnosis

 

Interface

Standard

 

 

RS232 x 1, Smart Slot x 2, Dry contact output x 6, Contact input x 2, Parallel port x 1,

 

 

 

 

 

Battery cabinet temperature x 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SNMP card, Modbus card, Relay I/O control card, Environmental monitoring box,

 

 

 

 

 

 

Optional Accessories

 

 

SNMP+ 5 ports hub, Battery cabinet temperature sensor,

 

 

 

 

 

 

Battery cabinet temperature kit (For Delta battery cabinet), Battery cabinet status cable

Confor- mance

Safety & EMC

 

 

 

 

CE, EN62040-1-1, EN62040-2(Class A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parallel Redundancy

 

 

 

 

Up to 4 cabinets

 

 

 

Emergency Power Off

 

 

 

 

Local and remote

 

 

Others

SRAM Event Log

 

 

 

 

500 records

 

 

Battery Temperature

 

 

 

 

 

Optional

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compensation

 

 

 

 

 

 

 

 

 

 

 

 

AC-Start

 

 

 

 

 

 

Yes

 

 

 

Battery-Start

 

 

 

 

 

 

Yes

 

 

 

Efficiency

Normal

 

 

 

 

94

 

 

 

ECO

 

 

 

 

97

 

 

 

 

 

 

 

 

 

 

 

Transfer Time

 

ms

 

 

 

 

0

 

 

Overall

Temperature

 

 

 

 

 

0 ~ 40

 

 

Relative Humidity

 

 

 

90 (non-condensing)

 

 

 

 

 

 

 

 

 

Noise (at one meter)

dBA

65

68

 

70

 

 

70

72

73

 

Dimension

UPS

mm

 

520x910x1165

 

 

 

520x975x1695

 

(WxDxH)

EBC**

520x850x1165 (26Ahx40pcs)

 

 

 

520x975x1695 (40Ahx40pcs)

 

 

 

 

 

 

Weight

 

kg

170

200

 

230

 

 

260

320

350

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Lower range 208~300 / 120~173Vac is acceptable under 70~100% loading condition.

**EBC: External battery cabinet.

All specifications are subject to change without prior notice.