Delta 23-665 Fastening Grinder to Supporting Surface, Connecting Tool to Power Source

Models: 23-665

1 10
Download 10 pages 26.84 Kb
Page 7
Image 7

2. Insert the short end of mounting rod (F) Fig. 7, into

hole of frame (B) and fasten in place with 1/4-20x3/4"

carriage head screw (G), 5/16” lock washer (H), and 1/4-

H G

F

20 hex nut (I).

3.Assemble long end of eye shield mounting rod (F) Fig. 7, to the side of each wheel guard using bracket (J), 3/8" lockwasher and locking knob (L). The eye shield (A) is fully adjustable so it can be put in any position by mov- ing the shield (A) or loosening locking knob (L) and repo- sitioning rod (F).

B I

Fig. 6

F

A

Fig. 7

J

L

FASTENING GRINDER TO SUPPORTING SURFACE

IF DURING OPERATION THERE IS ANY TENDENCY FOR THE GRINDER TO TIP OVER, SLIDE OR “WALK,” THE GRINDER MUST BE SECURED TO THE SUPPORTING SURFACE THROUGH THE TWO HOLES (A) FIG. 8, IN THE GRINDER BASE.

A

A

Fig. 8

CONNECTING TOOL TO POWER SOURCE

POWER CONNECTIONS

A separate electrical circuit should be used for your tools. This circuit should not be less than #12 wire and should be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3-prong grounding type plugs and 3-pole receptacles which accept the tool’s plug. Before connecting the motor to the power line, make sure the switch is in the “OFF” position and be sure that the electric current is of the same characteristics as indicated on the tool. All line connections should make good contact. Running on low voltage will damage the motor.

MOTOR SPECIFICATIONS

Your tool is wired for 120 volt, 60 HZ alternating current. Before connecting the tool to the power source, make sure the switch is in the “OFF” position. The motor provides a no-load speed of 3450 RPM.

GROUNDING INSTRUCTIONS

WARNING: THIS TOOL MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM ELECTRIC SHOCK.