PROBLEM

CAUSE

CORRECTION

 

Motor will not

Fuse blown, circuit breaker

Check fuse box for blown

 

run.

tripped.

fuse and replace as

 

 

 

 

necessary. Reset circuit

 

 

 

 

breaker. Do not use a fuse or

 

 

 

 

circuit breaker with higher

 

 

 

 

rating than that specified for

 

 

 

 

your particular branch circuit.

 

 

 

 

Check for proper fuse. You

 

 

 

 

should use a time delay fuse.

 

 

 

 

Check for low voltage

 

 

 

 

problem.

 

 

 

 

Check the extension cord.

 

 

 

 

Disconnect the other

 

 

 

 

electrical appliances from

 

 

 

 

circuit or operate the

 

 

 

 

compressor on its own

 

 

 

 

branch circuit.

 

 

 

Extension cord is wrong

Check the extension cord.

 

 

 

length or gauge.

 

 

 

 

Loose electrical

Check wiring connection

 

 

 

connections.

inside terminal box.

 

 

 

Faulty motor.

Have checked by a Trained

 

 

 

 

Service Technician.

 

 

 

 

 

 

19- ENG

D27449

Page 19
Image 19
Delta D27449, 66-500-1 instruction manual Problem Cause Correction