| PROBLEM | CAUSE | CORRECTION | |
Air leak from | Possible defect in safety | Operate safety valve | ||
safety valve. | valve. | manually by pulling on ring. | ||
|
|
| If valve still leaks, it should | |
|
|
| be replaced. | |
|
|
|
| |
Pressure reading | It is normal for "some" | If there is an excessive | ||
on the regulated | pressure drop to occur. | amount of pressure drop | ||
pressure gauge |
| when the accessory is used, | ||
drops when an |
| adjust the regulator following | ||
accessory is |
| the instructions in the | ||
used. |
| "Description of Operation" | ||
|
|
| paragraph in the "Operation | |
|
|
| Section. | |
|
|
| NOTE: Adjust the regulated | |
|
|
| pressure under flow | |
|
|
| conditions (while accessory | |
|
|
| is being used). | |
|
|
|
| |
Compressor is | Prolonged excessive use of | Decrease amount of air | ||
not supplying | air. | usage. | ||
enough air to |
| Check the accessory air | ||
operate | Compressor is not large | |||
accessories. | enough for air requirement. | requirement. If it is higher | ||
|
|
| than the SCFM or pressure | |
|
|
| supplied by your air | |
|
|
| compressor, you need a | |
|
|
| larger compressor. | |
|
| Hole in hose. | Check and replace if | |
|
|
| required. | |
|
| Air leaks. | Tighten fittings. | |
|
|
|
| |
Excessive | Condensation in tank | Drain tank | ||
"auto" starting |
|
|
| |
and stopping |
|
|
| |
|
|
|
|
|
D27930 | 16- ENG |