SERIES POWER ENTRY MODULE EMI FILTERS DVE

INTRODUCTIONS

SPECIFICATIONS

1.

AR series is designed as a high performance, two-stage filter for

1.

Maximum leakage current each

 

low impedance load with better noise attenuation than AK series

 

line-to-ground @ 115VAC 60Hz: 0.25mA

 

in low frequency applications such as switching power supplies.

 

@ 250VAC 50Hz: 0.45mA

2.

Fuse holder designed for one IEC 5x20mm fuse. Safety interlock

2.

Hipot rating (one minute)

 

prevents fuse removal with line plug inserted (Use only with 250V

 

line-to-ground: 2250VDC

 

fuse).

 

line-to-line: 1450VDC

3.

All part numbers are UL recognized, CSA certified and VDE

3.

Operating frequency: 50/60Hz

 

approved.

4.

Rated voltage: 115/250VAC

COMPONENTS

MINIMUM INSERTION LOSS IN dB

PART NO.

C1 (uF)

L1 (mH)

L2 (mH)

Cy (pF)

R ( )

03AR1/2/3

0.1

1.5

9

2200

1M

03AR2D/3D

0.033

9

1.5

 

 

06AR1/2/3

0.1

0.7

2.5

3300

2.2M

06AR2D/3D

0.015

2.5

0.7

06AR4

0.1

0.7

2.5

 

 

ELECTRICAL SCHEMATIC

AR1/4 WITHOUT POWER SW

AR3/4 ONLY

COMMON MODE (L-G) IN 50 OHM SYSTEM

CURRENT

 

FREQUENCY-MHz

 

 

RATING

.15

.50

1.0

5.0

10

30

03AR

40

60

60

45

40

30

06AR

34

55

56

40

35

25

06AR2D,3D

34

60

60

45

40

30

DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM

 

03AR

6

45

55

50

45

40

06AR

5

25

60

50

45

35

06AR2D,3D

10

10

50

50

45

40

L

L F SW1

I

N

E

N

G

C1

L1

Cy

Cy

R

 

L'

C2

L

C3

O

L2

A

N' D

G'

L

L F SW1

I

N

E

N

G

AR3D ONLY

 

 

L'

Cy

R C2

L

C1

C3

L1

 

O

 

L2

 

 

A

Cy

 

N' D

 

 

G'

FIG. A

C2:0.1uFC3:0.1uF

FIG. B

POWER ENTRY MODULE FILTERS

TYPE & RATED CURRENT

DELTA PART NO.

AR1

AR2

AR2D

AR3

AR3D

AR4

RATED CURRENT

115VAC

6A

6A

6A

6A

6A

6A

 

250VAC

6A

6A

4A

5A

4A

6A

IEC CONNECTOR

 

 

 

 

 

 

 

FUSE HOLDER

 

 

SP1

DP2

SP1

DP2

 

POWER SWITCH

 

 

 

VOLTAGE SELECTOR SW

 

 

 

REAR3

REAR3

REAR3

ELECTRICAL SCHEMATIC

FIG. A

FIG. A

FIG. B

FIG. A

FIG. B

FIG. A

1.Single-pole UL, CSA & VDE approved, VDE-6A at 250VAC. Electrical lifetime: 50,000 cycles.

Maximum inrush current: 50A.

2.Double-pole UL, CSA & VDE approved, VDE-4A at 250VAC. Electrical lifetime: 10,000 cycles.

Maximum inrush current: 50A.

3.Voltage selector SW -UL, CSA & VDE approved Current rating: 10A at 125VAC; 5A at 250VAC.

4-3

Page 1
Image 1
Delta Electronics AR specifications Introductions Specifications, Components, Electrical Schematic, Type & Rated Current