KHB 120 x 54 MM SERIES
New
DIMENSIONS DRAWING
| 120.0 | 0.5 |
( | 4.724 | 0.020) |
| 98.5 | 0.5 |
( | 3.878 | 0.020) |
54.00.8
(2.126 0.031)
40.50.5
(1.594 0.020)
47.00.5
(1.850 0.020)
M4(5X)
(ONE FOR GROUNDING)
M4(4X)
47.0 0.5 | 1.850 0.020) | 58.0 0.5 | 2.283 0.020) | 65.0 0.5 | ( 2.559 0.020) |
| ( |
| ( |
|
|
10.0 | (0.394) | 80.0 10.0 | (3.150 0.394) | 345.0 10.0 | (13.583 0.394) |
mm
UNIT :
(INCH)
* Bearing Type |
Ball Bearings |
Material |
P & Q CURVE (AT RATED VOLTAGE) | MOUNTING PANEL CUTOUT |
* |
Impeller : Plastic (UL |
Pillow : |
* Lead Wires : |
UL 1007 AWG #24 Or Equivalent |
Red Wire Positive (+) |
Black Wire Negative |
* Weight : 330g (11.64 oz) |
| 2.0 |
|
|
| KHB1248XXS |
|
|
| ||
| 50.0 |
|
|
|
|
|
|
|
| |
| 1.6 | 40.0 |
|
|
|
|
| EH |
|
|
Pressure | 0.8 | 20.0 |
|
|
|
|
| SH |
| 2.0 |
| 1.2 | 30.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VH |
| |
Air | 0.4 | 10.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 0.0 | 0.0 | 0 | 1.0 | 2.0 | 3.0 | 4.0 | 5.0 | 6.0 | (M3/MIN) |
| O) | O) | ||||||||
|
|
|
|
|
|
|
|
| ||
| 2 | 2 | 0 | 40 | 80 | 120 | 160 | 200 | (CFM) | |
| H | H | ||||||||
| (IN | (mm |
|
| Air Flow |
|
|
|
| |
|
|
|
|
|
|
|
|
|
| *INLET RING: |
|
|
| |
REF.) |
| 146.0 REF. | 18.0 | (0.709) | |
( | 5.748 REF.) | ||||
|
|
| |||
|
| 96.0 REF. |
|
| |
| ( | 3.780 REF.) |
|
| |
(0.079 | .0 |
|
|
| |
R16 |
|
|
| ||
| .630) |
|
|
| |
| (R0 |
|
|
|
mm
UNIT :
(INCH)
|
| Rated | Operating | Input | Input |
| Maximum | Maximum |
| ||||
MODEL | Voltage | Speed | Noise | ||||||||||
Voltage | Current | Power | Air Flow | Air Pressure | |||||||||
|
| Range |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
| |||
PART NO. | FUNCTION | VDC | VDC | Amp | Watt | R.P.M. |
| CFM | mmH2 O | IN H 2 O | |||
KHB1248VHS | 48 | 32.0 | to 80.0 | 0.27 | 12.96 | 3100 | 3.520 | 124.30 | 20.60 | 0.810 | 53.5 | ||
KHB1248SHS | 48 | 32.0 | to 80.0 | 0.35 | 16.80 | 3500 | 4.000 | 141.30 | 27.00 | 1.070 | 57.5 | ||
KHB1248EHS |
| 48 | 32.0 | to 80.0 | 0.47 | 22.56 | 4100 | 4.680 | 165.30 | 38.20 | 1.500 | 61.5 |
*Function type is optional.
*The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
*Noise is measured in anechoic chamber in free air, one meter from intake side.
*All readings are typical values at rated voltage.
*Specifications are subject to change without notice.
132
http://www.deltaww.com