Delta Electronics KPE-LE02 instruction sheet X 鍵盤面板外觀, Z功能顯示項目說明, Z Display Messages, 鍵盤面板鍵盤面板尺寸

Models: KPE-LE02

1 2
Download 2 pages 17.07 Kb
Page 1
Image 1
20071112
20071112

5011666101-K201

KPE-LE02Digital Keypad for VFD-E Series

Instruction Sheet

Please thoroughly read this instruction sheet before installation and putting it into use.

The content of this instruction sheet and the driver file may be revised without prior notice. Please consult our distributors or download the most updated instruction version at http://www.delta.com.tw/industrialautomation.

XDescription of the Digital Keypad

YDimensions in mm [inch]

Display Message

Descriptions

Displays “Err”, if the input is invalid.

[How to Operate the Digital Keypad

Setting Mode

START

GO START

NOTE: In the selected mode, press KPE-LE02Digital Keypad for VFD-E Series to set the parameters.

Setting parameters

 

or

 

 

 

Success to

Input data error

set parameter.

 

 

 

NOTEIn the parameter setting mode, you can press Instruction Sheet to the selected mode.

To change data

Setting direction (When operation source is digital keypad)

KPE-LE02 VFD-E系列之數位操作器

說明書

請詳細閱讀下列說明後才使用本產品,以確保使用安全。

由於產品精益求精,當內容規格有所修正時,請洽詢代理商或至台達網站 (http://www.delta.com.tw/industrialautomation )下載最新版本。

X鍵盤面板外觀

Y

71.9 [2.83]

25.9 [1.02]

 

42.4 [1.67]

16.3 [0.64]

8.6 [0.34]

M3*0.5(2X)

34.3 [1.35]XDescription of the Digital Keypad

1.5 [0.06]

52.4 [2.06]

61.0 [2.40]

Setting PLC Mode

PLC2 mode active

鍵盤面板鍵盤面板尺寸

 

 

71.9 [2.83]

25.9 [1.02]

8.6 [0.34]

52.4 [2.06]

 

 

M3*0.5(2X)

 

 

42.4 [1.67]

34.3 [1.35]

 

8.1 [0.32]

ZDisplay Messages

Display Message

Descriptions

Displays the AC drive Master Frequency.

Displays the actual output frequency at terminals U/T1, V/T2, and W/T3.

User defined unit (where U = F x Pr.00.05)

Displays the output current at terminals U/T1, V/T2, and W/T3.

Displays the AC motor drive forward run status.

Displays the AC motor drive reverse run status.

The counter value (C).

Displays the selected parameter.

Displays the actual stored value of the selected parameter.

External Fault.

Displays “End” for approximately 1 second if input has been accepted by

pressing [How to Operate the Digital Keypad key. After a parameter value has been set, the new value

is automatically stored in memory. To modify an entry, use the KPE-LE02 VFD-E系列之數位操作器 and X鍵盤面板外觀 keys.

PLC1 mode active

\Installation

Method 1. Direct installation (unit: mm[inch])

Method 2. Mounting by the plate thickness (unit: mm[inch])

A.Thickness=1.2mm[0.05 inches]

B.Thickness=2.0mm[0.08 inches]

16.3 [0.64]

1.5 [0.06]

61.0 [2.40]

 

 

8.1 [0.32]

Z功能顯示項目說明

 

 

顯示項目

 

說明

顯示驅動器目前的設定頻率

 

顯示驅動器實際輸出到馬達的頻率

 

顯示用戶定義之物理量 (U = F x 00-05)

顯示負載電流

 

 

正轉命令

 

 

反轉命令

 

 

顯示計數值

 

 

顯示參數項目

 

 

顯示參數內容值

 

 

外部異常顯示

 

 

若由顯示區讀到 End 的訊息(如左圖所示)大約一秒鐘,表示資料已被接受並

自動存入內部存貯器

 

 

若設定的資料不被接受或數值超出時即會顯示

Page 1