SPECIFICATIONS
GENERAL SPECIFICATIONS | OUTPUT SPECIFICATIONS | ||||
Input Voltage |
| 18~75V | Voltage Accuracy | Typical | ±1% |
Switching Frequency | Typical (5V) | 300KHz | Line Regulation | Typical | ±0.1% |
Isolation Voltage | In/Out | 2250V | Load Regulation | Typical | ±0.1% |
Isolation Capacitance | Typical | 1500PF | Ripple & Noise | Typical | 50 mV |
Isolation Resistance | Minimum | 100MΩ | Current Limits | Typical | 130% |
MTBF | Bellcore (3.3V) | 3.72M hrs | Over Voltage | Typical | 120% |
OTP | Typical | 115°C | Voltage Trim |
| +10%, |
Size | (1.95”x1.55”x0.35”) | 49.6x39.4x8.9mm |
|
|
|
PART NUMBERING | SYSTEM |
|
|
|
|
| L | 36 |
| S |
| A |
| 050 |
| 10 | N |
| R | F |
| A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Type of | Input | Number of | Product |
| Output | Output | ON/OFF |
| Pin |
|
| Option Code | ||||
| Product | Voltage | Outputs | Series |
| Voltage | Current | Logic | Length |
|
|
|
| ||||
| L - 2 x 1.6 | 18~75V | S - Single | A - 50W | 3R3- 3.3V | 04- 4A | N- Negative | R- 0.170” | F- RoHS 6/6 |
| A- Standard | ||||||
| Brick |
|
|
| platform |
| 050- 5.0V | 10- 10A | P- Positive |
|
| (Lead Free) |
| Functions | |||
|
|
|
|
|
|
|
| 120- 12V | 15- 15A |
|
|
|
| B- With sense | |||
| MODEL | LIST |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MODEL NAME |
|
| INPUT |
|
|
| OUTPUT |
| EFF @ 100% LOAD |
| ||||||
| L36SA3R315NRFA |
| 18V~75V |
|
| 2.1A |
| 3.3V | 15A |
|
| 88% |
|
|
| ||
| L36SA05010NRFA |
| 18V~75V |
|
| 1.9A |
| 5.0V | 10A |
|
| 89% |
|
|
| ||
| L36SA12004NRFA |
| 18V~75V |
|
| 1.9A |
| 12V | 4A |
|
| 87.5% |
|
|
|
MECHANICAL DRAWINGS
Open Frame Version
CONTACT: www.delta.com.tw/dcdc
USA: | East Coast: (888) 335 8201 | Europe: | Asia & the rest of world: | |
Phone: | Phone: +41 31 998 53 11 | Telephone: +886 3 4526107 ext 6220 | ||
| West Coast: (888) 335 8208 | Fax: +886 3 4513485 | ||
| Fax: +41 31 998 53 53 | |||
Fax: (978) 656 3964 | Email: DCDC@delta.com.tw | |||
Email: | ||||
Email: |
| |||
|
|
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any 2 patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice.