SFP timing parameters for SFP management

 

Parameter

 

Symbol

Min.

 

Max.

 

Unit

 

Note

 

 

TX_DISABLE Assert time

t_off

 

10

 

sec

1

 

 

TX_DISABLE Negate time

 

t_on

 

 

1

 

msec

 

2

 

 

Time to initialize, including

t_init

 

300

 

msec

3

 

 

reset of TX_FAULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TX Fault Assert Time

 

t_fault

 

 

100

 

sec

 

4

 

 

TX_DISABLE to reset

t_rest

10

 

 

 

sec

5

 

 

LOS Assert Time

 

t_loss_on

 

 

100

 

sec

 

6

 

 

LOS Deassert Time

t_loss_off

 

100

 

sec

7

 

 

Serial ID Clock Rate

 

f_serial_clock

 

 

100

 

kHz

 

 

 

Notes:

1)Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal

2)Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal

3)From power on or negation of TX_Fault using TX Disable

4)Time from fault to TX fault on.

5)Time TX Disable must be held high to reset TX_Fault

6)Time from LOS state to Rx LOS assert

7)Time from non-LOS state to Rx LOS deassert

8

Oct., 2006

 

Rev. 6F

DELTA ELECTRONICS, INC.

www.deltaww.com

Page 8
Image 8
Delta Electronics LCP-1250A4FDRx specifications SFP timing parameters for SFP management, Parameter Symbol Min Max Unit