SFP timing parameters for SFP management
| Parameter |
| Symbol | Min. |
| Max. |
| Unit |
| Note |
|
| TX_DISABLE Assert time | t_off |
| 10 |
| ∝sec | 1 |
| |||
| TX_DISABLE Negate time |
| t_on |
|
| 1 |
| msec |
| 2 |
|
| Time to initialize, including | t_init |
| 300 |
| msec | 3 |
| |||
| reset of TX_FAULT |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| ||
| TX Fault Assert Time |
| t_fault |
|
| 100 |
| ∝sec |
| 4 |
|
| TX_DISABLE to reset | t_rest | 10 |
|
|
| ∝sec | 5 |
| ||
| LOS Assert Time |
| t_loss_on |
|
| 100 |
| ∝sec |
| 6 |
|
| LOS Deassert Time | t_loss_off |
| 100 |
| ∝sec | 7 |
| |||
| Serial ID Clock Rate |
| f_serial_clock |
|
| 100 |
| kHz |
|
|
|
Notes:
1)Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal
2)Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal
3)From power on or negation of TX_Fault using TX Disable
4)Time from fault to TX fault on.
5)Time TX Disable must be held high to reset TX_Fault
6)Time from LOS state to Rx LOS assert
7)Time from
8 | Oct., 2006 |
| Rev. 6F |
DELTA ELECTRONICS, INC. | www.deltaww.com |