Delta Electronics LCP-2125 Absolute Maximum Ratings, Recommended Operating Conditions, Receiver

Models: LCP-2125

1 14
Download 14 pages 54.03 Kb
Page 2
Image 2
Absolute Maximum Ratings

Absolute Maximum Ratings

 

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

 

Storage Temperature

Ts

-40

 

85

ºC

 

 

Supply Voltage

VCC

0

 

5

V

 

Recommended Operating Conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

 

Case Operating Temperature

TC

-5

 

70

ºC

1

 

Supply Voltage

VCC

3.135

 

3.465

V

 

 

Note 1: See order information

 

 

 

 

 

 

Electrical Characteristics

 

 

 

 

 

 

(VCC=3.3V ± 5%)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

 

Total Supply Current

ICCT

 

180

300

mA

 

 

Transmitter

 

 

 

 

 

 

 

Transmitter Differential Input Voltage

VDT

0.5

 

2.4

V

1

 

Transmitter Disable Input-High

VDISH

2

 

VCC+0.3

V

 

 

Transmitter Disable Input-Low

VDISL

0

 

0.8

V

 

 

Transmitter Fault Pull up Resistor

RTX_FAULT

4.7

 

10

kΩ

2

 

Transmitter Fault Output-High

VTXFH

2

 

VCC+0.3

V

 

 

Transmitter Fault Output-Low

VTXFL

0

 

0.8

V

 

 

Receiver

 

 

 

 

 

 

 

Receiver Differential Output Voltage

VDR

0.35

 

2.0

V

3

 

Receiver LOS Load

RRXLOS

4.7

 

10

kΩ

2

 

LOS Output Voltage-High

VLOSH

2

 

VCC+0.3

V

 

 

LOS Output Voltage-Low

VLOSL

0

 

0.8

V

 

 

Output Data Rise/Fall Time

tr / tf

 

 

2.5

nsec

4

Notes:

1.Internally AC coupled and terminated to 100Ohm differential load.

2.Pull up to VCC on host Board.

3.Internally AC coupled, but requires a 100Ohm differential termination at or internal to Serializer/ Deserializer.

4.These are 20%~80% values.

2

Nov., 2006

 

Rev. 1D

DELTA ELECTRONICS, INC.

www.deltaww.com

Page 2
Image 2
Delta Electronics LCP-2125 Absolute Maximum Ratings, Recommended Operating Conditions, Electrical Characteristics, Symbol