ΝήΨϟ΍ Ε΍ήΘϣ΍έΎΑ Δϔϴχϭ : ΔΜϟΎΜϟ΍ ΔϋϮϤΠϤϟ΍

ϊϨμϤϟ΍ ςΒο

Ε΍Ω΍ΪϋϹ΍

ϒ΋ΎχϮϟ΍

Ε΍ήΘϣ΍έΎΒϟ΍

1.0

1.0 ~ 400 Hz

ϑΪϬϟ΍ ΩΩήΘϟ΍

3-00

 

 

 

 

0

0 ~ 999

Δϴ΋ΎϬϨϟ΍ Ϊόϟ΍ ΔϤϴϗ

3-01

0

0 ~ 999

Δϴ΋΍ΪΘΑϻ΍ Ϊόϟ΍ ΔϤϴϗ

3-02

 

ϡΪΨΘδϣ ήϴϏ : 0

 

 

 

ήΗήϔϧϻ΍ ϞϤϋ ˯ΎϨΛ΃ ϞϤόΗ : 1

 

 

 

ϖϘΤϤϟ΍ ϲϤψϋϷ΍ ΝήΨϟ΍ ΩΩήΗ : 2

 

 

 

Δϳήϔμϟ΍ Δϋήδϟ΍ : 3

 

 

 

ϡΰόϟ΍ ίϭΎΠΗ : 4

 

 

 

ϞϴϐθΘϟ΍ ΓΩΎϋ· : 5

 

 

 

ξϔΨϨϤϟ΍ ΪϬΠϟ΍ ΔψΣϼϣ : 6

 

 

8

ήΗήϔϧϻ΍ ϞϤϋ ςϤϧ : 7

 

 

 

Ϟτόϟ΍ ϰϠϋ ΔϟϻΪϟ΍ : 8

( ϪϴϠϳήϟ΍ ΝήΧ ) ΓΩΪόΘϤϟ΍ ϒ΋ΎχϮϟ΍

 

 

ϑΪϬϟ΍ ΩΩήΘϠϟ ϝϮλϮϟ΍ : 9

 

3-03

 

PLC ΞϣΎϧήΑ ϞϴϐθΗ : 10

 

 

 

 

 

PLC ΞϣΎϧήΑ ΓϮτΧ ϝΎϤΘϛ΍ : 11

 

 

 

PLC ΞϣΎϧήΑ ϝΎϤΘϛ΍ : 12

 

 

 

PLC ΞϣΎϧήΑ ϞϤόϟ ΖϗΆϣ ϑΎϘϳ· : 13

 

 

 

ΔϘϘΤϤϟ΍ Δϴ΋ΎϬϨϟ΍ Ϊόϟ΍ ΔϤϴϗ :14

 

 

 

ΔϘϘΤϤϟ΍ Δϴ΋΍ΪΘΑϻ΍ Ϊόϟ΍ ΔϤϴϗ : 15

 

 

 

ΔϳΰϫΎΠϟ΍ ΔϟΎΣ ϰϠϋ ΔϟϻΪϟ΍ : 16

 

 

ϞΧΪϟ΍ Ε΍ήΘϣ΍έΎΑ Δϔϴχϭ : ΔόΑ΍ήϟ΍ ΔϋϮϤΠϤϟ΍

ϊϨμϤϟ΍ ςΒο

Ε΍Ω΍ΪϋϹ΍

ϒ΋ΎχϮϟ΍

Ε΍ήΘϣ΍έΎΒϟ΍

 

 

 

 

 

ΩΩήΘϟ΍ ΔϤϴϗ ΡΎϳΰϧ΍

 

 

0.0

 

 

0.0 ~ 350 Hz

ΓΎϨϗ ΩΩήΗ ΔϤϴϗ Ϧϋ

4-00

 

 

 

 

 

ΔϴϬΑΎθΘϟ΍ ϞΧΪϟ΍

 

 

0

 

 

ΐΟϮϣ ΡΎϳΰϧ΍ : 0

ϑ΍ήΤϧ΍ ΔϴΒτϗ

4-01

 

 

 

ΐϟΎγ ΡΎϳΰϧ΍ : 1

αΎϴϘϤϟ΍

 

 

 

 

 

 

100

 

 

1 ~ 200 %

ϞΧΪϟ΍ ΩΩήΗ ΢Αέ

4-02

 

 

 

ϲϬΑΎθΘϟ΍

 

 

 

 

 

 

 

 

 

 

ϡΪΨΘδϣ ήϴϏ : 0

ϥ΍έϭΪϟ΍ βϜϋ ϦϴϜϤΗ

 

 

0

 

 

ΔϨϜϤϣ ΔϛήΤϟ΍ βϜϋ : 1

ϞΧΪϟ΍ Δτγ΍ϮΑ

4-03

 

 

 

 

ςϘϓ ΔϴϣΎϣ΃ ΔϛήΣ : 2

ϲϬΑΎθΘϟ΍

 

 

 

 

 

ϡΪΨΘδϣ ήϴϏ : 0

ϒ΋Ύχϭ ϭΫ ϞΧΩ

 

 

 

ϲδϜϋ/ ϑΎϘϳ· :M1 ˬ ϲϣΎϣ΃/ϑΎϘϳ· :M0 : 1

 

 

1

ϲϣΎϣ΃/ϲδϜϋ :M1ˬ ϞϴϐθΗ/ ϑΎϘϳ· : M0 : 2

ΓΩΪόΘϣ

4-04

 

 

ϙϼγ΃ ΔΛϼΛ ϢϜΤΘϟ΍ ΔϴϠϤϋ ωϮϧ : M0 , M1, M2: 3

( M1) 1 ϞΧΪϟ΍

 

 

 

 

 

ΎϴόϴΒσ˱

ΡϮΘϔϣ ˬ ϲΟέΎΧ Ϟτϋ : 4

 

 

 

 

ΎϴόϴΒσ˱

ϖϠϐϣ ˬ ϲΟέΎΧ Ϟτϋ : 5

ϒ΋Ύχϭ ϭΫ ϞΧΩ

 

 

 

 

 

ήϴϔμΗ : 6

 

 

6

1 ϞΧΪϣ – ΓΩΪόΘϤϟ΍ ΕΎϋήδϟ΍ έΎϴΘΧ΍ ήϣ΃ : 7

ΓΩΪόΘϣ

4-05

 

 

2 ϞΧΪϣ – ΓΩΪόΘϤϟ΍ ΕΎϋήδϟ΍ έΎϴΘΧ΍ ήϣ΃ : 8

( M2) 2 ϞΧΪϟ΍

 

 

 

 

 

( ϱϭΪϴϟ΍ ϞϴϐθΘϟ΍ ) Jog ˰ϟ΍ ΔϴϠϤϋ : 9

 

 

 

 

(ΆσΎΒΘϟ΍/ωέΎδΘϟ΍ ϝΎϤϛ· ϊϨϣ) ΔϴϟΎΤϟ΍ Δϋήδϟ΍ ΖϴΒΜΗ : 10

 

 

 

 

ϲϧΎΜϟ΍ ϭ΃ ϝϭϷ΍ ωέΎδΘϟ΍ / ΆσΎΒΘϟ΍ Ϧϣί έΎϴΘΧ΍ : 11

ϒ΋Ύχϭ ϭΫ ϞΧΩ

 

 

7

ΎϴόϴΒσ˱ ΡϮΘϔϣ ˬ ϞϴϐθΘϟ΍ ΓΩΎϋ· : 12

ΓΩΪόΘϣ

4-06

 

ΎϴόϴΒσ˱

ϖϠϐϣ ˬ ϞϴϐθΘϟ΍ ΓΩΎϋ· : 13

( M3) 3 ϞΧΪϟ΍

 

 

 

 

 

 

 

 

Ϊ΋ΎϘϟ΍ ΩΩήΗ ΓΩΎϳί : 14

 

 

 

9

Page 10
Image 10
Delta Electronics VFD-L Series manual ϠΪΨΘδϣ ήϴϏ ΉΗήϔϧϻ ϞϤϋ ˯ΎϨΛ ϞϤόΗ, ΘΪϬϟ ΩΩήΘϠϟ ϝϮλϮϟ PLC ΞϣΎϧήΑ ϞϴϐθΗ, PLC ΞϣΎϧήΑ ϝΎϤΘϛ

VFD-L Series specifications

Delta Electronics has established itself as a leader in variable frequency drive (VFD) technology, with the introduction of the VFD-L Series serving as a testament to their commitment to innovation and performance. These drives are designed specifically for various applications in industries such as HVAC, pumps, fans, and conveyors, offering users enhanced control and energy efficiency.

One of the main features of the VFD-L Series is its compact design, which allows for easy installation even in space-constrained environments. The drives are built with a rugged casing that provides excellent protection in harsh operating conditions, making them ideal for industrial settings. With power ratings spanning from 0.4 kW to 37 kW, the VFD-L Series caters to a wide range of applications, ensuring that users can find the right solution to meet their needs.

Incorporating advanced control algorithms, the VFD-L Series enhances motor performance while maintaining energy efficiency. The drives utilize Vector Control technology, which provides precise speed and torque control for AC induction and permanent magnet motors. This capability allows for smooth acceleration and deceleration, minimizing mechanical stress on equipment and prolonging lifespan.

The VFD-L Series is equipped with a built-in programmable logic controller (PLC) functionality, enabling users to customize control sequences without the need for additional external devices. This feature simplifies system design and enhances operational flexibility. Additionally, the user-friendly interface allows for easy programming and monitoring, making it accessible for both novice and experienced users.

Another noteworthy characteristic is the incorporation of energy-saving features. The VFD-L Series includes sleep mode and automatic energy optimization functions that proactively adjust the motor’s power consumption based on the actual load requirements. This not only reduces operational costs but also contributes to environmental sustainability by lowering carbon emissions.

Furthermore, Delta Electronics has ensured that the VFD-L Series is compliant with international standards, providing users with confidence in their reliability and safety. With built-in protection features like overvoltage, undervoltage, overload, and short-circuit protection, these drives provide a secure operating environment for sensitive equipment.

In conclusion, Delta Electronics’ VFD-L Series combines advanced technology, robust features, and a compact design to deliver exceptional performance across various industrial applications. With a focus on energy efficiency and user-friendly accessibility, the VFD-L Series is a powerful solution for modern manufacturing and automation needs. Whether for HVAC systems or material handling, this series stands out as an innovative choice for businesses looking to enhance their operational efficiency.