Ver.3.09

 

Data : Mar.24.2008

35 page of 50

1.9.19SACD Layer Selsect

This selects the layer of SACD.

byte \ bit

7

6

5

 

4

 

 

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

STX

( 02h )

 

 

 

 

1

 

 

 

Command code

( ' O ' )

 

 

2

 

 

 

 

Layer

code

( *1

)

 

 

 

3

 

 

 

 

Reserve

(00h)

 

 

 

 

4

 

 

 

 

Reserve

(00h)

 

 

 

 

5

 

 

 

 

Reserve

(00h)

 

 

 

 

6

 

 

 

 

Reserve ( 00h )

 

 

 

 

7

 

 

 

 

ETX ( 03h )

 

 

 

 

8

 

 

 

 

BCCH ( high-level )

 

 

9

 

 

 

 

BCCH

( low-level )

 

 

( *1)

Layer

code

Code

 

Layer

 

 

 

 

31h

(1)

 

2ch Layer

32h

(2)

 

Multi ch Layer

33h

(3)

 

CD Layer

1)Answers returned

byte \ bit

7

6

5

4

 

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

STX

(02h)

 

 

 

 

1

 

 

 

Reply

code ( ' O

' )

 

 

2

 

 

 

Answer code

 

 

 

 

3

 

 

 

ETX ( 03h )

 

 

 

 

4

 

 

 

BCCH ( high-level )

 

 

5

 

 

 

BCCH

( low-level )

 

 

2)Special conditions

When status code is 4Bh (DIR mode) , this command is not accepted.

Copyright 2008