www.desatech.com
114248-01B 7

SHUTTING OFF HEATER

For short periods of time, turn the main burner
off by turning control knob clockwise to the
PILOT position.
For extended periods of non use, turn appli-
ance completely off by turning control knob
clockwise to the PILOT position, press knob
slightly, then turn knob fully clockwise to
the OFF position. Note: For propane/LP gas
models, also turn off gas supply cylinder.)

PILOT BURNER ADJUSTMENT

1. Remove pilot adjustment cap. The pilot adjust-
ment cap is a slotted screw located in front
of the PILOT designation stamped on top of
valve body just below control knob.
2. Adjust pilot key to provide properly sized
flame. Rotate the key clockwise to decrease
flame or counterclockwise to increase flame.
3. Replace pilot adjustment cap.
MAINTENANCE

WARNING:

• Never attempt to service

heater while it is connected to

propane supply, operating or

hot. Severe burns can occur.

• Keep heater clear and free

from combustible materials,

gasoline and other flammable

vapors and liquids.

• Do not block the flow of com-

bustion or ventilation air.

1. Keep heater clean. Clean heater annually or as
needed to remove dust and debris. If heater is
dirty or dusty, clean heater with a damp cloth.
Use household cleaners on difficult spots.
2. Inspect heater before each use. Check connec-
tions for leaks. Apply mixture of liquid soap
and water to connections. Bubbles forming
show a leak. Correct all leaks at once.
3. Inspect hose/regulator assembly before each
use. If hose is highly worn or cut, replace.
4. Have heater inspected yearly by a qualified
service agency.
OPERATING
INSTRUCTIONS

Continued

SPECIFICATIONS
Propane/LP Model 125-R
Rating
125,000 Btu/Hr (131,882 kj)
Fuel Propane Vapor Only
Fuel Consumption per Hour
5.17 liters (1.3 gallon)
2.6 kg (5.8 pounds)
Supply Pressure To Regulator (for input adjustment)
Maximum 1380 kPa (200 psi)
Minimum 138 kPa (20 psi)
Manifold Pressure 2.3 kPa (9.5 inches W.C.)
Weight
Heater 17.69 kg (39 lbs)
Shipping 20.86 kg (46 lbs)
Size - L x W x H 40.6 x 45.7 x 109.2 cm
(16 x 18 x 43 inches)
Min Temperature -29 °C (-20° F) Surrounding
Air Temperature
Natural Gas Model 125-RN
Rating
125,000 Btu/Hr (131,882 kj)
Fuel Natural Gas Only
Fuel Consumption
per Hour 3.5 m3 (125 ft3)
Manifold Pressure 1.5 kPa (6 inches W.C.)
Weight
Heater 17.69 kg (39 lbs)
Shipping 20.86 kg (46 lbs)
Size - L x W x H 40.6 x 45.7 x 109.2 cm
(16 x 18 x 43 inches)
Min Temperature -29 °C (-20° F) Surrounding
Air Temperature