PITCH

 

 

SLOPE

OPENING "A" MAX

USE FLASHING

 

 

 

 

 

 

 

(degrees)

 

 

 

(inches)

MODEL NO.

 

 

 

FLAT

0

 

 

 

 

15

 

 

 

 

 

V6F-8DM

 

 

 

0 - 6/12

 

26.6

 

 

 

 

16 - 1/8

 

 

 

 

 

V6F-8DM

 

 

 

6/12 - 12/12

 

45.0

 

 

 

 

20 - 3/8

 

 

 

 

 

V12F-8DM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 14 ROOF OPENING CHART

FLASHING INSTALLATION (V6F-8DM or V12F-8DM) Determine the flashing to be used with the roof opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nailing through shingles (see figure 15).

DO NOT NAIL THROUGH FLASHING CONE.

Figure 15

FLASHING INSTALLATION

INSTALLING FLASHING ON A METAL ROOF

When installing the flashing on a metal roof, it is required that putty tape be used between the flashing and the roof. The flashing must be secured to the roof using #8 x ¾” screws and then sealed with roof coating to prevent leakage through the screw holes. A roof coating must also be applied around the perimeter of the flashing to provide a proper seal.

STORM COLLAR INSTALLATION (SC1)

Place storm collar over pipe and slide down until it is snug against the open edge of the flashing (see figure 16). Apply waterproof caulk around the perimeter of the collar to provide a proper seal.

Note: Storm collar is required but can be installed after the home is sited.

Figure 16

STORM COLLAR

TERMINATIONS / SPARK ARRESTOR

The fireplace system must be terminated with the listed round top or chase terminations. In any case, refer to the installation instructions supplied with the termination. The terminations approved for this fireplace are the RTL-8DM, which can be use for flashing or chase and the ETL-8DM, for chase style termination only. Figure 17 shows an RTL-8DM round top termination.

 

 

 

 

 

 

 

 

 

Figure 17

TERMINATION

 

 

 

 

CAUTION: Do not seal openings on the rooftop flashing. Follow the installation instructions provided with the termination being used.

NOTE: In the rare instance there is a problem with the side driven rain or wind or the chimney is not drafting properly, an ADS-8DM Anti Draft Shield can be used with round terminations.

- 7 -

For more information, visit www.desatech.com

Page 8
Image 8
Desa C36EMW Flashing Installation, Installing Flashing on a Metal Roof, Storm Collar Installation SC1, Termination

C36EMW specifications

Desa C36EMW is an innovative model that represents significant advancements in modern living. Designed to enhance comfort and efficiency, this unit has garnered attention for its thoughtful features and cutting-edge technology.

One of the standout characteristics of the Desa C36EMW is its energy-efficient design. Equipped with an advanced heating system, it utilizes smart thermodynamic technology that maximizes heating output while minimizing energy consumption. This results in a cozy environment without the excessive energy costs that are often associated with traditional heating systems.

The model adopts a sleek, modern aesthetic, making it a suitable addition for various interior designs. Its compact dimensions mean it can fit seamlessly into small and large spaces alike. The exterior is crafted from durable materials that not only enhance the unit's lifespan but also ensure easy maintenance.

In terms of technology, the Desa C36EMW incorporates intelligent climate control features. With a built-in thermostat and Wi-Fi connectivity, users can adjust settings remotely, allowing for pre-emptive temperature adjustments before arriving home. This feature not only adds convenience but also assists in maintaining an optimal living environment at all times.

The Desa C36EMW also emphasizes user-friendly operation. The interface boasts an easy-to-read digital display that simplifies the process of selecting various settings. Additionally, the model supports programmable schedules, allowing users to customize their heating needs throughout the week based on their unique routines.

Safety is a paramount consideration in the design of the Desa C36EMW. It includes multiple safety features such as overheat protection and tip-over shut-off, ensuring peace of mind for families and individuals.

Furthermore, the Desa C36EMW is designed with an eco-conscious approach, producing low emissions to align with sustainability efforts. This means users can enjoy the comfort of heating without compromising on environmental responsibility.

In conclusion, the Desa C36EMW is a remarkable blend of efficiency, technology, and safety. Its modern design, energy-saving capabilities, and user-friendly features make it an ideal choice for anyone looking to enhance their living space while keeping energy costs low. With its commitment to sustainability and user comfort, the Desa C36EMW sets a benchmark in the heating appliance market.