CGCFTN
INSTALLATION
Continued
Extension Cord
Use extension cord if needed. The cord must have a
ATTACHING WOOD BASE TO SOLID FLOOR
For attaching base to solid floors (concrete or masonry)
Note: Floor anchors and mounting screws are in hardware package. The hardware pack- age is provided with fireplace.
1.Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or masonry), drill at least 1" deep.
2.Fold floor anchor as shown in Figure 22.
3.Insert floor anchor (wings first) into hole. Tap anchor flush to floor.
4.Insert mounting screws through base and into floor anchors.
5.Tighten screws until base is firmly fas- tened to floor.
Figure 22 - Folding Anchor
CONNECTING TO GAS SUPPLY
WARNING: This appliance re- quires a 45° male flare fitting 5/8"- 18 UNF (Unified National Fine Thread) inlet connection and the flexible gas line provided.
WARNING: A qualified ser- vice person must connect fire- place to gas supply. Follow all local codes.
WARNING: Never connect fireplace to private
IMPORTANT: Check gas line pressure before connecting fireplace to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, fireplace regulator damage could occur.
CAUTION: Use only new, black iron or steel pipe. Inter-
Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 23).
IMPORTANT: Install an equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on and shutting off the gas to the appliance.
Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.
We recommend that you install a sediment trap in supply line as shown in Figure 23. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps mois- ture and contaminants. This keeps them from going into fireplace controls. If sedi- ment trap is not installed or is installed wrong, fireplace may not run properly.
CSA
Equipment Shutoff Valve
With 1/8" NPT Tap*
Approved
Flexible
Gas Line
| From Gas |
| Meter |
| (5" W.C. to |
| 10.5" W.C. |
3" Minimum | Pressure) |
Pipe Nipple Cap Tee Joint
Sediment Trap
Figure 23 - Gas Connection
*Purchase the optional CSA
14 | 107035 |