Desa CGD3018N, CGD3930N installation manual Ventilation AIR, Ventilation Air From Inside Building

Models: CGD3018N CGD3930N

1 40
Download 40 pages 45.48 Kb
Page 7
Image 7

AIR FOR

WARNING

COMBUSTION

 

If the area in which the heater may be operated is smaller than

 

AND

that defined as an unconfined space, provide adequate combus-

tion and ventilation air by one of the methods described in the

VENTILATION

National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3.

Continued

VENTILATION AIR

 

 

Ventilation Air From Inside Building

 

This fresh air would come from an adjoining unconfined space. When ventilating to an

 

adjoining unconfined space, you must provide two permanent openings: one within 12"

 

of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see

 

options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3,

 

Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air

 

for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING

Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

 

 

12"

Ventilation

 

Ventilation Grills

Grills

 

Into Adjoining

Or

Into Adjoining Room,

Room,

Option 2

Remove

Option 1

 

Door into

 

 

 

 

Adjoining

 

 

Room,

 

 

Option

 

 

3

 

 

 

12"

Figure 2 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat- controlled power vent. Heated air entering the attic will activate the power vent.

 

Outlet

Ventilated

 

 

Attic

 

 

Air

 

 

 

 

Outlet

 

 

 

Air

 

To Attic

 

 

 

 

 

 

To

 

 

 

Crawl

 

Inlet

 

Space

 

 

 

 

Air

 

 

 

 

Inlet Air

Ventilated

 

 

Crawl Space

 

 

 

 

Figure 3 - Ventilation Air from Outdoors

7

102990

Page 7
Image 7
Desa CGD3018N, CGD3930N Ventilation AIR, Ventilation Air From Inside Building, Ventilation Air From Outdoors

CGD3018N, CGD3930N specifications

The Desa CGD3930N and CGD3018N are innovative gas heaters that exemplify cutting-edge technology and design in the heating industry. Both models are designed to provide efficient heating solutions for residential spaces, ensuring comfort during colder months while being environmentally conscious.

The CGD3930N is a powerful unit featuring a heating capacity of up to 30,000 BTUs, making it suitable for larger areas. It combines radiant and convection heating methods to ensure even heat distribution throughout the space. This model is equipped with a thermostat for precise temperature control, allowing users to set their desired comfort level easily. One of its standout features is the built-in oxygen depletion sensor, which enhances safety by monitoring the air quality to prevent hazardous conditions.

On the other hand, the CGD3018N, with a heating capacity of 18,000 BTUs, is perfect for smaller rooms or spaces that require consistent heating without excessive energy consumption. Its compact design makes it adaptable for various room layouts. Like the CGD3930N, it also features an adjustable thermostat, ensuring users can maintain the preferred level of warmth. The heater's flameless design provides a safe alternative to traditional heating methods, reducing the risk of accidents.

Both models utilize advanced ceramic burner technology, which enhances combustion efficiency and reduces emissions. This is particularly important as households increasingly seek to minimize their environmental footprint. This technology also ensures that both heaters operate quietly, providing warmth without the disruption of noisy mechanisms.

A significant aspect of the Desa CGD3930N and CGD3018N is their versatility. They can be installed as wall-mounted units or freestanding options, giving homeowners the flexibility to choose the best configuration for their space. The modern aesthetic of both models complements a wide range of interior designs, making them not only functional but stylish additions to any home.

In conclusion, the Desa CGD3930N and CGD3018N are excellent choices for those seeking reliable and efficient heating solutions. With their advanced features, safety measures, and stylish designs, these gas heaters provide warmth and comfort in any residential environment while promoting energy efficiency.