24

TROUBLE- SHOOTING

Continued

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

Burner(s) does not

1.

Burner orifice(s) is

1.

Clean burner orifice(s)

light after ODS/pilot

 

clogged

 

(see Cleaning and Main-

is lit

 

 

 

tenance, page 22) or re-

 

 

 

 

place burner orifice(s)

 

2.

Burner orifice(s)

2.

Replace burner orifice(s)

 

 

diameter is too small

 

 

 

3.

Inlet gas pressure is

3.

Contact local natural gas

 

 

too low

 

company

 

 

 

 

 

Delayed ignition of

1.

Manifold pressure is

1.

Contact local natural gas

burner(s)

 

too low

 

company

 

2.

Burner orifice(s) is

2.

Clean burner orifice(s)

 

 

clogged

 

(see Cleaning and Main-

 

 

 

 

tenance, page 22) or re-

 

 

 

 

place burner orifice(s)

 

 

 

 

 

Burner backfiring

1.

Burner orifice(s) is

1.

Clean burner orifice(s)

during combustion

 

clogged or damaged

 

(see Cleaning and Main-

 

 

 

 

tenance, page 22) or re-

 

 

 

 

place burner orifice(s)

 

2.

Burner damaged

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

Burner plaque(s) does

1. Plaque damaged

1.

Replace burner

not glow

2.

Inlet gas pressure is

2.

Contact local natural gas

 

 

too low

 

company

 

3.

Control knob set

3.

Turn control knob until it

 

 

between locked

 

locks at desired setting

 

 

positions

 

 

 

 

 

 

Slight smoke or odor

1. Residues from manu-

1.

Problem will stop after a

during initial opera-

 

facturing processes

 

few hours of operation

tion

 

 

 

 

 

 

 

 

Heater produces a

1. Metal expanding while

1.

This is common with

clicking/ticking noise

 

heating or contracting

 

most heaters. If noise is

just after burner is lit

 

while cooling

 

excessive, contact quali-

or shut off

 

 

 

fied service person

099434

Page 24
Image 24
Desa CGN18R, CGN30C installation manual See Cleaning and Main