VENT-FREE PROPANE/LP GAS HEATER

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nau- sea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to propane/LP gas. The odor helps you detect a propane gas leak. However, the odor added to propane/LP gas can fade. Propane/LP gas may be present even though no odor exists.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not use any accessory not approved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will re- main hot for a time after shut- down. Allow surface to cool be- fore touching.

Carefully supervise young chil- dren when they are in the same room with heater.

Make sure grill guard is in place before running heater.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.Heater shall not be installed in a bath- room.

5.This heater needs fresh, outside air ven- tilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6.

6.Keep all air openings in the front and bottom of heater clear and free of de- bris. This will insure enough air for proper combustion.

7.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

8.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

9.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

10.Do not use heater if any part has been under water. Immediately call a quali- fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

11.Turn off heater and let cool before ser- vicing. Only a qualified service person should service and repair heater.

12.Operating heater above elevations of 4,500 feet could cause pilot outage.

13.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

2

104268

Page 2
Image 2
Desa CGP10TLA, CGP10TA installation manual VENT-FREE PROPANE/LP GAS Heater, Safety Information

CGP10TLA, CGP10TA specifications

Desa CGP10TA and CGP10TLA are advanced generator models known for their reliability and performance in various applications. These generators are designed to cater to both residential and light commercial needs, providing an efficient power solution anytime and anywhere.

One of the most notable features of the CGP10TA and CGP10TLA is their robust engine performance. These generators are powered by a high-quality, air-cooled four-stroke engine that ensures durability and long operational life. Their engines are optimized for fuel efficiency, enabling users to minimize operational costs while maximizing usability.

The CGP10TA and CGP10TLA models come equipped with automatic voltage regulation (AVR) technology. This feature guarantees stable voltage output, which is essential for sensitive electronic devices. By maintaining consistent voltage levels, the generators protect appliances from potential damage caused by power surges or fluctuations, thereby enhancing user confidence.

Safety is another priority in the design of these generators. Both models include essential safety features such as low-oil shutdown, which automatically turns off the engine when oil levels drop below a certain threshold. This safeguard helps prevent engine damage and prolongs the generator's lifespan, making it a wise choice for conscientious users.

Portability is a standout characteristic of the Desa CGP10TA and CGP10TLA generators. Each unit is designed with a lightweight frame, convenient carrying handles, and rubber wheels, allowing for easy transportation to various locations. Whether you need backup power during a storm, for camping, or to support outdoor events, these generators are versatile and user-friendly.

Moreover, these generators are engineered for quiet operation. Their noise-reduction technologies ensure a peaceful environment, making them suitable for residential areas and outdoor gatherings where excessive noise could be disruptive. Users can enjoy reliable power without the worry of disturbing neighbors or losing the tranquility of nature.

In terms of connectivity, both models include multiple AC and DC outlets, making it easy to power various devices simultaneously. Whether it's lights, power tools, or electronics, these generators can handle the load with ease, providing versatility for any power needs.

In conclusion, the Desa CGP10TA and CGP10TLA generators represent a blend of performance, safety, and convenience. With their advanced engine technology, automatic voltage regulation, safety features, portability, and quiet operation, they stand out as excellent choices for anyone in need of reliable, efficient, and user-friendly power solutions.