10,000 AND 6,000 BTU/HR PROPANE/LP GAS HEATER

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, etc. (See IMPORTANT

 

 

statement above)

 

2.

Low fuel supply

 

3.

Gas leak. See Warning statement at

 

 

top of page

1.Ventilate room. Stop using odor-causing products while heater is running

2.Refill supply tank

3.Locate and correct all leaks (see Check- ing Gas Connections, page 9)

1.

Not enough fresh air is available

1.

Open window and/or door for ventila-

Heater shuts off in use (ODS operates)

 

 

tion

2.

Low line pressure

2.

Contact local propane/LP gas company

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

Maintenance, page 11)

 

 

 

 

Gas odor even when control knob is in OFF 1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

top of page

 

ing Gas Connections, page 9)

2.

Control valve defective

2.

Replace control valve

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 9)

Moisture/condensation noticed on windows 1. Not enough combustion/ventilation air. 1. Refer to Fresh Air for Combustion and Venti-lationrequirements (page 3)

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at 1-800-323-5190.

SERVICE HINTS

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

When gas quality is bad

pilot will not stay lit

burner will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

ACCESSORY

Purchase this heater accessory from your local dealer. If they cannot supply this ac- cessory, either contact your nearest Parts Central (see page 15) or call DESA International’s Parts Department at 1-800- 972-7879 for referral information. You can also write to the address listed on the back page of this manual.

MANUAL SHUTOFF

VALVE - GA5010

Manual shutoff valve with 1/8" NPT tap.

14

103547

Page 14
Image 14
Desa CGP6L, CGP10L installation manual Technical Service, Service Hints, Accessory

CGP10L, CGP6L specifications

Desa's CGP10L and CGP6L are two innovative gas-powered heating solutions designed for both residential and commercial applications. These models highlight an impressive combination of efficiency, convenience, and modern technology tailored to meet diverse heating needs.

The CGP10L is a robust heater with a capacity of 10,000 BTUs, making it an ideal choice for larger spaces or areas requiring extensive heating. In contrast, the CGP6L offers a slightly lower output of 6,000 BTUs, perfect for smaller rooms or as supplemental heating in larger environments. Both models are designed to deliver reliable warmth while maintaining energy efficiency, which is crucial for cost-effective household management.

One of the standout features of the CGP10L and CGP6L is the use of advanced infrared technology. This technology allows for quick and efficient heating by warming objects and people directly rather than merely heating the air. As a result, users can experience immediate comfort without the typical waiting times associated with traditional heating systems.

In terms of design, both models feature a compact and lightweight construction, enabling easy portability. This is particularly beneficial for users who may want to move their heater from room to room or even take it outdoors. The built-in safety features, such as automatic shut-off functions and tip-over protection, enhance the safety profile of these units, making them suitable for various living conditions.

Moreover, Desa has incorporated user-friendly controls in both models, allowing users to adjust the heat output according to their comfort preferences. The straightforward operation ensures that even those who are not technically inclined can benefit from these powerful heating systems.

The fuel efficiency of the CGP10L and CGP6L is another attractive characteristic, as both models are designed to minimize gas consumption while maximizing heat output. This not only contributes to lower utility bills but also aligns with eco-friendly practices.