LIGHTING

OWNER’S MANUAL

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information page 10, column 3.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise TO SELECT to the OFF position.

4.Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation page 10, column 3. If you don’t smell gas, go to the next step.

5.Press in and turn control knob coun-

terclockwise TO TURN OFF GAS TO to PILOT/IGN position. Press in control knob for five (5) seconds (see Figure 16).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, you may need to press in control knob for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or supplier for repairs.

6.Release downward pressure on con-

trol knob and turn clockwise Shutting Off Heater to OFF position.

7.Press in control knob and turn back to PILOT/IGN. This will cause the piezo ignitor to spark and light the pilot gas. If needed, repeat steps 5 through 7 until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 13 through 15. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

8 . Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

Figure 16 - Control Knob In The OFF Position

 

Ignitor Electrode

Thermocouple

Pilot Burner

 

Figure 17 - Pilot

TO SELECT

HEATING LEVEL

Shutting Off Burner Only (pilot stays lit) WARNING: When running heater, set control knob at LOW or HIGH locked positions. Never set control knob between locked positions. Poor combustion and higher levels of carbon monox- ide may result.

MANUAL LIGHTING CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

Slightlypressincontrolknobandturncoun-

terclockwiseManual backgroundtotheLOWorHIGH positions (see Figure 18).

IMPORTANT: Release downward pres- sure while turning control knob. Control knob will lock at the desired position.

Control

Knob Burners

Figure 18 - Burner Patterns

TO TURN OFF GAS TO

APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise Manual background to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Manual background to the PILOT/IGN position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions.

2.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.