OWNER’S MANUAL

SPECIFICATIONS

 

FA-10BA

FA-60BA

FAS-10BB

Btu (Variable)

6,000/10,000

6,000

10,000

Type Gas

Natural Only

Natural Only

Natural Only

Ignition

Piezo

Piezo

Piezo

Pressure Regulator Setting

3" W.C.

3" W.C.

3" W.C.

Inlet Gas Pressure (inches of water)

 

 

 

Maximum

10.5"

10.5"

10.5"

Minimum

4"

4"

4"

Dimensions, Inches (H x W x D)

 

 

 

Heater

18 x 14 x 5

18 x 14 x 5

18 x 14 x 5

Carton

21 x 16 x 7

21 x 16 x 7

21 x 16 x 7

Weight (pounds)

 

 

 

Heater

12.9

12.9

13.3

Shipping

15

15

15.4

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190.

You can also visit DESA International’s technical service web site at www.desatech.com.

SERVICE HINTS

When Gas Pressure is Too Low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

When Gas Quality is Bad

pilot will not stay lit

burner will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

SERVICE PUBLICATIONS

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

105564