NATURAL GAS HEATER
INSTALLATION
Continued
CHECKING GAS
CONNECTIONS
WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.
WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG (3.5 K Pa)
1.Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator.
2.Cap off open end of gas pipe where equipment shutoff valve was connected.
3.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.
4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.
5.Correct all leaks at once.
6.Reconnect heater and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 K Pa)
1.Close equipment shutoff valve (see Fig- ure 13).
2.Pressurize supply piping system by either using compressed air or open- ing main gas valve located on or near gas meter.
3. Check all joints from gas meter to | OPERATING | |||
| equipment shutoff valve (see Figure | HEATER | ||
| 14). Apply mixture of liquid soap and | |||
| water to gas joints. Bubbles forming |
| ||
| show a leak. |
| FOR YOUR SAFETY | |
4. | Correct all leaks at once. |
| ||
| READ BEFORE | |||
|
|
| ||
Pressure Testing Heater Gas | LIGHTING | |||
Connections |
|
| ||
1. Open equipment shutoff valve (see Fig- | WARNING: If you do not fol- | |||
| ure 13). |
| low these instructions exactly, a | |
2. Open main gas valve located on or near | fire or explosion may result caus- | |||
| gas meter. |
| ing property damage, personal | |
3. Make sure control knob of heater is in | injury or loss of life. | |||
| ||||
| the OFF position. |
| A. This appliance has a pilot which must | |
4. | Check all joints from equipment shutoff | |||
be lighted by hand. When lighting the | ||||
| valve to control valve (see Figure 14). | |||
| pilot, follow these instructions exactly. | |||
| Apply mixture of liquid soap and water to | |||
| B. BEFORE LIGHTING smell all | |||
| gas joints. Bubbles forming show a leak. | |||
5. | Correct all leaks at once. |
| around the appliance area for gas. Be | |
| sure to smell next to the floor because | |||
6. Light heater (see Operating Heater, | ||||
some gas is heavier than air and will | ||||
| pages 10 and 11). Check the rest of the | settle on the floor. | ||
| internal joints for leaks. |
| WHAT TO DO IF YOU SMELL | |
7. Turn off heater (see To Turn Off Gas to | ||||
GAS | ||||
| Appliance, page 11). |
| • Do not try to light any appliance. | |
8. | Replace front panel. |
| • Do not touch any electric switch; do | |
|
|
| not use any phone in your building. | |
|
|
| • Immediately call your gas supplier | |
Equipment | Open | from a neighbor’s phone. Follow | ||
Shutoff Valve |
| the gas supplier’s instructions. | ||
|
|
| • If you cannot reach your gas sup- | |
|
|
| plier, call the fire department. | |
|
|
| C. Use only your hand to push in or turn | |
|
| Closed | the gas control knob. Never use tools. | |
|
| If the knob will not push in or turn | ||
|
|
| by hand, don’t try to repair it, call a | |
Figure 13 - Equipment Shutoff Valve | qualified service technician or gas | |||
|
| Control | supplier. Force or attempted repair | |
|
| may result in a fire or explosion. | ||
|
| Valve | ||
|
| Location | D. Do not use this appliance if any part | |
|
|
| has been under water. Immediately | |
|
|
| call a qualified service technician to | |
| Gas Meter |
| inspect the appliance and to replace | |
|
| any part of the control system and | ||
|
|
| any gas control which has been un- | |
|
|
| der water. | |
|
| Equipment | ||
|
| Shutoff |
| |
|
| Valve |
| |
Figure 14 - Checking Gas Joints |
|
10 | 105562 |