Desa FB-10BA installation manual Installation

Models: FB-10BA

1 26
Download 26 pages 52.83 Kb
Page 7
Image 7

OWNER’S MANUAL

INSTALLATION

LOCATING HEATER

This heater is designed to be mounted on a wall.

CEILING

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary

WARNING: Maintain the mini- mum clearances shown in Figure

4. If you can, provide greater clear-

ances from floor, ceiling, and

6" Minimum From Sides of Heater

36" Minimum

heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heating source.

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply is not propane/LP, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have the items listed below:

external regulator (supplied by installer, see page 9)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

ground joint union

test gauge connection *

sediment trap

tee joint

pipe wrench

*An CSA/AGA design-certified equip- ment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connec- tion. The optional CSA/AGA design-certi- fied equipment shutoff valve can be pur- chased from your dealer. See Accessory, page 18.

joining wall.

WARNING: Never install the heater

in a bathroom (Models FB- 10BA and FBS-10BB only. FB- 60BA is allowed in bathroom. Check local codes.)

in a recreational vehicle

where curtains, furniture, cloth- ing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Fresh Air for Com- bustion and Ventilation, pages 4 through 6.

CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor

locate heater where moving ve- hicle will not hit it

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

in coldest part of room

Right

Side

Left

Side

2" Minimum to Top

FLOOR of Carpeting, Tile,

or Other Combustible Material

Figure 4 - Mounting Clearances As Viewed From Front of Heater

INSTALLING HEATER TO WALL

Mounting Bracket

The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel.

Mounting

Bracket

Figure 5 - Mounting Bracket

INSTALLING THERMOSTAT SENSING BULB -

For T-Stat Models Only

Remove clip and bulb from shipping loca- tion. Place clip and bulb into operation loca- tion (see Figure 6)

Figure 6 - Moving Thermostat Sensing Bulb

Continued

105565

7

Page 7
Image 7
Desa FB-10BA installation manual Installation

FB-10BA specifications

Desa FB-10BA is a remarkable addition to the world of portable heating solutions, designed to deliver efficient warmth in a variety of settings. Standing out in the market for its user-friendly features and robust technology, it’s a popular choice among homeowners and professionals alike.

One of the main features of the Desa FB-10BA is its impressive heating capacity. It can efficiently warm spaces of up to 1,000 square feet, making it suitable for large garages, workshops, or any sizeable room. The powerful output of 10,000 BTU ensures that users can achieve the desired temperature quickly and maintain it consistently throughout colder months.

Incorporating advanced ceramic technology, the FB-10BA utilizes a ceramic heat exchanger that promotes quick and effective heating. This design not only enhances the performance but also contributes to energy efficiency. Consumers benefit from reduced energy consumption while still enjoying full functionality, helping to save on heating costs.

The unit operates on propane, a clean-burning fuel source that minimizes environmental impact compared to traditional fuels. Its portability is another significant characteristic; the FB-10BA is equipped with a rugged handle and a lightweight design, enabling easy transport from one location to another.

Safety features are paramount in the design of the Desa FB-10BA. The built-in automatic shut-off mechanism activates in case of overheating or when the unit is tipped over, providing peace of mind for users. Additionally, it comes with an adjustable thermostat that allows for precise temperature control, enabling users to customize their heating experience according to their needs.

The flexibility of the FB-10BA is further highlighted by its ability to run both indoors and outdoors, making it a versatile option for camping trips, outdoor gatherings, or simply heating up a chilly garage or workshop. The durable construction ensures that it can withstand the rigors of different environments, offering longevity and reliability.

In summary, the Desa FB-10BA combines efficiency, portability, and safety in a well-designed heating solution. Its powerful heating capacity, advanced ceramic technology, and user-friendly features make it a valuable asset for anyone looking to stay warm during the colder months while enjoying the advantages of modern heating technologies.