Desa FBS-10BB, FB-60BA For Your Safety Read Before Lighting, Thermostat Control Operation

Models: FBS-10BB FB-60BA

1 26
Download 26 pages 52.77 Kb
Page 12
Image 12

PROPANE/LP GAS HEATER

OPERATING

HEATER

Continued

THERMOSTAT MODEL FBS-10BB

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con- trol which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, column 1.

2.Make sure equipment shutoff valve is fully open.

3.Push in control knob slightly and turn

clockwise to the OFF position (see Figure 19). Be sure that the tem- perature setting knob is set at the line between level 1 and level 7.

4.Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation in column 1. If you don’t smell gas, go to the next step.

5.Push in and turn control knob coun-

terclockwise to PILOT po- sition. Press in control knob for five(5) seconds.

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, you may need to press in control knob for 30 seconds. This will allow air to bleed from the gas system.

6.Release downward pressure on con-

trol knob and turn clockwise to OFF position.

7.Press in control knob and turn coun-

terclockwise past IGN to PILOT (see Figure 19). This will cause the piezo ignitor to spark and light the pilot gas. Keep control knob depressed for 10 seconds before re- leasing. If needed, repeat steps 5 through 7 until pilot lights.

 

 

PILOT

6

 

IGN

5

 

ON

 

7

 

4

1

OFF

 

 

3

2

 

Figure 19 - Dual Control for Thermostat Model FBS-10BB

Thermocouple

Ignitor Electrode

Pilot

 

 

Burner

Figure 20 - Pilot

Note: If pilot does not stay lit, refer to Troubleshooting, pages 14 through

16.Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 13.

8 . When pilot is lit, turn the ignition knob to ON position (see Figure 19).

9.To select desired heating level, turn the temperature setting knob coun-

terclockwise between 1 and 7 (see Figure 19).

TO TURN OFF GAS TO

APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT

CONTROL

OPERATION

The thermostatic control used on this model differs from standard thermo- stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room tem- perature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any comfort level between 1 and 7.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depend- ing on housing construction, installation location, room size, open air tempera- tures, etc.) Frequent use of your heater will let you determine your own comfort levels.

12

107299

Page 12
Image 12
Desa FBS-10BB, FB-60BA installation manual For Your Safety Read Before Lighting, Thermostat Control Operation

FBS-10BB, FB-60BA specifications

The Desa FB-60BA and FBS-10BB are advanced innovations in the field of heating solutions, specifically designed to cater to a variety of residential and commercial heating needs. Both models exemplify efficiency and reliability while incorporating modern technologies to enhance user experience.

The FB-60BA is a powerful and versatile heater that ensures optimal warmth during the cold months. With a sleek design, this model seamlessly fits into any environment, providing not only functionality but also aesthetic appeal. It features an adjustable thermostat that allows users to maintain their desired temperature effortlessly. The FB-60BA also includes safety features such as an automatic shut-off mechanism in case of overheating, providing peace of mind to users.

On the other hand, the FBS-10BB is designed for portability and convenience. This compact heater is lightweight yet powerful, making it easy to move from room to room. Its fan-forced heat distribution system ensures that warmth reaches every corner of the space, making it ideal for quick heating in smaller areas. The FBS-10BB also boasts a quiet operation, allowing users to enjoy consistent heating without disruptive noise.

Both models utilize advanced heating technologies that optimize energy efficiency. They are designed to consume less energy while providing maximum heating output, which is a significant advantage for environmentally conscious consumers. This efficiency is achieved through the use of high-quality heating elements and innovative engineering that minimizes energy loss.

In terms of characteristics, the FB-60BA offers a range of wattage options, allowing users to select the level of heat that best suits their needs. Its durable construction ensures longevity, even under frequent use. The FBS-10BB, on the other hand, offers quick heat-up times, ensuring that users feel the benefits of the heater in a matter of moments.

Both models come with user-friendly controls, making them accessible to everyone, with straightforward settings for temperature adjustments and power levels. The aesthetics of these heaters, combined with their robust performance and technological advancements, make them standout choices for any heating requirement.

In conclusion, the Desa FB-60BA and FBS-10BB represent the fusion of style, safety, and energy efficiency in heating solutions. Their unique features and cutting-edge technologies cater to a wide range of consumer needs, ensuring comfort and satisfaction during cold weather conditions.